Background and purpose: In-vivo dosimetry is used to ensure accurate delivery of dose to tumors during radiotherapy. This study aimed at measuring the entrance doses without the build-up cap for patients undergoing 15MV radiotherapy and determining the percentage errors between doses measured by films and those calculated with a treatment planning system (TPS). Materials and methods: The stu...

2015
Samantha A.M. Lloyd Sergei Zavgorodni Isabelle M. Gagne

Dosimetric comparisons of radiation fields produced by Varian's newest linear accelerator, the TrueBeam, with those produced by older Varian accelerators are of interest from both practical and research standpoints. While photon fields have been compared in the literature, similar comparisons of electron fields have not yet been reported. In this work, electron fields produced by the TrueBeam a...

2015
Hong-Wei Liu James Gräfe Rao Khan Ivo Olivotto J Eduardo Villarreal Barajas

PURPOSE To evaluate the role of in vivo dosimetry with radiochromic films for dose verification in cutaneous radiation therapy (RT). METHODS Five patients with 8 cutaneous or sub-cutaneous malignancies of the face, neck, trunk and extremity receiving RT were included. Orthovoltage, megavoltage photon therapies were applied based on anatomic location. The delivered dose for each target was mea...

2016
Moti R. Paudel Anthony Kim Arman Sarfehnia Sayed B. Ahmad David J. Beachey Arjun Sahgal Brian M. Keller

A new GPU-based Monte Carlo dose calculation algorithm (GPUMCD), devel-oped by the vendor Elekta for the Monaco treatment planning system (TPS), is capable of modeling dose for both a standard linear accelerator and an Elekta MRI linear accelerator. We have experimentally evaluated this algorithm for a standard Elekta Agility linear accelerator. A beam model was developed in the Monaco TPS (res...

Journal: :Medical physics 2013
A Schoenfeld R Crilly B Poppe W Laub

PURPOSE Implants with high atomic numbers produce star-like artifacts in CT-images. When coupled in pairs, a black window appears in between. The Philips OMAR algorithm approaches these artifacts by post processing the images. In this study, measurements were performed with radiochromic EBT2 films in order to verify, whether the OMAR algorithm contributes to the accuracy of treatment plans in i...

Journal: :Medical physics 2016
R Underwood

PURPOSE To determine the feasibility of using radiochromic and radiographic film with Pipspro software for quality assurance of linear accelerators with no on-board imaging. METHODS The linear accelerator being used is a Varian Clinac 21EX. All IGRT is performed using the BrainLab ExacTrac system. Because of the lack of on board imaging, certain monthly and annual TG-142 quality assurance tes...

2015
Ren‐Dih Sheu Allison Powers Yeh‐Chi Lo

This study provides the authors' experience along with dosimetric data from the commissioning of two Sensus SRT-100 50-100 kV X-ray units. Data collected during the commissioning process included: a) HVL, b) output (dose rate), c) applicator cone factors, and d) percentage depth dose. A Farmer-type chamber (PTW-N23333), and a thin-window parallel plate ion chamber (PTW-N23342) were used for dos...

Journal: :Radiation Physics and Chemistry 2023

This work tackles the commissioning and validation of a novel combination synchrotron-based proton beam therapy system (Hitachi, Ltd.) for use with Monte Carlo treatment planning (TPS). Four crucial aspects in this configuration have been investigated: (1) Carlo-based correction performed by TPS to measured integrated depth-dose curves (IDD), (2) circular spot modelling single Gaussian function...