نتایج جستجو برای: dose verification

تعداد نتایج: 384124  

Journal: :Polish Journal of Medical Physics and Engineering 2022

Abstract Introduction: In vivo dosimetry verification is currently a necessity in radiotherapy centres Europe countries as one of the tools for patient-specific QA, and now its demand rising developed countries, such Malaysia. The aim this study to characterize commercial EPID-based implementation treatment Materials Methods: work, sensitivity performance commercially available system, EPIgray®...

Journal: :Medical physics 2005
S Steciw B Warkentin S Rathee B G Fallone

A three-dimensional (3D) intensity-modulated radiotherapy (IMRT) pretreatment verification procedure has been developed based on the measurement of two-dimensional (2D) primary fluence profiles using an amorphous silicon flat-panel electronic portal imaging device (EPID). As described in our previous work, fluence profiles are extracted from EPID images by deconvolution with kernels that repres...

Journal: :Medical physics 2001
M Oldham J H Siewerdsen A Shetty D A Jaffray

The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that...

2015
Yuji Nakaguchi Takeshi Ono Masato Maruyama Nozomu Nagasue Yoshinobu Shimohigashi Yudai Kai

In this study, we evaluated the performance of a three-dimensional (3D) dose verification system, COMPASS version 3, which has a dedicated beam models and dose calculation engine. It was possible to reconstruct the 3D dose distributions in patient anatomy based on the measured fluence using the MatriXX 2D array. The COMPASS system was compared with Monte Carlo simulation (MC), glass rod dosimet...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2008
Christopher M Bragg Katrina Wingate John Conway

PURPOSE To determine the implications of the use of the Anisotropic Analytical Algorithm (AAA) for the production and dosimetric verification of IMRT plans for treatments of the prostate, parotid, nasopharynx and lung. METHODS 72 IMRT treatment plans produced using the Pencil Beam Convolution (PBC) algorithm were recalculated using the AAA and the dose distributions compared. Twenty-four of t...

2010
Sathiyan Saminathan Ravikumar Manickan Varatharaj Chandraraj Sanjay. S. Supe

Intensity-modulated radiotherapy treatment demands stringent quality assurance and accurate dose determination for delivery of highly conformal dose to the patients. Generally 3D dose distributions obtained from a treatment planning system have to be verified by dosimetric methods. Mainly, a comparison of two-dimensional calculated and measured data in several coplanar planes is performed. In p...

Journal: :Physics and Imaging in Radiation Oncology 2023

Inter- and intra-fractional prostate motion can deteriorate the dose distribution in extremely hypofractionated intensity-modulated proton therapy. We used verification CTs data calculated from 1024 records to develop a voxel-wise based 4-dimensional method, which had time resolution of 1 second, assess impact motion. An example 100 fractional simulations revealed that minimal on planning dose,...

2013
A Quinn

Imaging procedures utilised for patient position verification during breast radiotherapy can add a considerable dose to organs surrounding the target volume on top of therapeutic scatter dose. This study investigated the dose from a breast kilovoltage cone-beam CT (kV-CBCT), a breast megavoltage fan-beam CT (MV-FBCT), and a TomoDirect breast treatment. Thermoluminescent dosimeters placed within...

2015
Jinhan Zhu Lixin Chen Along Chen Guangwen Luo Xiaowu Deng Xiaowei Liu

PURPOSE To use a graphic processing unit (GPU) calculation engine to implement a fast 3D pre-treatment dosimetric verification procedure based on an electronic portal imaging device (EPID). METHODS The GPU algorithm includes the deconvolution and convolution method for the fluence-map calculations, the collapsed-cone convolution/superposition (CCCS) algorithm for the 3D dose calculations and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید