Kristofer Kainz Douglas Prah Ergun Ahunbay X. Allen Li

"Burst-mode" modulated arc therapy (hereafter referred to as "mARC") is a form of volumetric-modulated arc therapy characterized by variable gantry rotation speed, static MLCs while the radiation beam is on, and MLC repositioning while the beam is off. We present our clinical experience with the planning techniques and plan quality assurance measurements of mARC delivery. Clinical mARC plans fo...

2014
Atsushi Fukuda Pei‐Jan P. Lin Kosuke Matsubara Tosiaki Miyati

The purpose of this study was to develop and evaluate a simple method to assess gantry rotation overrun in a single axial CT scanning. The exposure time in the axial scanning was measured at selected nominal rotation times (400, 700, and 1000 ms) using a solid-state detector, the RTI's CT dose profiler (CTDP). CTDP was placed at the isocenter and the radiation dose rate signal (profile) was rec...

2017
Molham M. Eyadeh Marcin Wierzbicki Kevin R. Diamond

In external beam radiation therapy (EBRT), skin dose measurement is important to evaluate dose coverage of superficial target volumes. Treatment planning systems (TPSs) are often inaccurate in this region of the patient, so in vivo measurements are necessary for skin surface dose estimation. In this work, superficial dose distributions were measured using radiochromic translucent poly(vinyl alc...

2015
Lifeng Zhu Kai Wei Wei Huan Wu

Gantry structure has the advantages of easy production, high bearing capacity, stability and so on. It is widely used in engineering. There is an optimal solution for different structural parameters in gantry. In the practical engineering application, the safety factor is higher, which can meet the load demand, and the weight is less. In this paper, the advantages and disadvantages of the colum...

2010
Ilya Tyapin Geir Hovland

One of the main advantages of the Gantry-Tau machine is a large accessible workspace/footprint ratio compared to many other parallel machines. The Gantry-Tau improves this ration further by allowing a change of assembly mode without internal link collisions or collisions between the links and end-effector. The reconfigurable Gantry-Tau kinematic design obtained by multi-objective optimisation a...

2015
Pejman Rowshanfarzad Peter Häring Hans L Riis Sune J Zimmermann Martin A Ebert

BACKGROUND In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evalu...

2011
Mike Oliver Karl Bush Sergei Zavgorodni Will Ansbacher Wayne A. Beckham

The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into an in-house computer program that introduced delivery errors. Random and syst...

2010
John P. Mullins Michael G. Herman

Mechanical flex of the gantry and mounted imaging panels leads to systematic offsets in localization image isocenter as a function of gantry angle for linear accelerator-mounted image guidance systems. Subsequently, object positions obtained from localization radiographs may be offset, resulting in greater target positioning uncertainty. While current QA procedures measure kV/MV image agreement...