نتایج جستجو برای: bone wires

تعداد نتایج: 317060  

2012
B. Cem Şener

Biomaterial is a nonviable substance used in a medical device intended to interact with biological systems. Their usage within a physiologic medium needs the characteristic features such as efficient and reliable. These characteristic features have provided with a suitable combination of chemical, mechanical, physical and biological properties [2]. Nowadays, biomaterials are commonly used in va...

2015
Jialiang Zhu Yantao Zhao Lin Yang Shuxun Hou Yanli Su Rungong Yang

In this study we report antibacterial modification of Kirschner wires (K-wires) with polyluteolin (PL) toward methicillin-resistant Staphylococcus aureus (MRSA). K-wires were modified by immersing them in the luteolin-containing aqueous solution for 24 h. Characterizations using scanning electron microscopy and electrochemical methods confirmed the presence of the PL coatings on the K-wires. Th...

2014
Sheng LI Min ZHOU

The smart cable with embedded distributed fiber optical Bragg grating (FBG) sensors was chosen as the object to study a new diagnosis method about broken wires of bridge cable. The diagnosis strategy based on cable force and stress distribution state of steel wires was put forward. By establishing bridge cable and cable steel wires model, the broken wires sample database was simulated numerical...

2008
Jennifer Long John E. Savage

Decoders are employed to address individual NWs in crossbars (xbars) used for storage and computation. We report on the simulation and analysis of a membranebased nanowire (NW) decoder proposed by Pribat and Savage [1] that implements the randomized-contact decoder (RCD) introduced by Williams and Kuekes [2] and analyzed by Hogg et al [3] and Rachlin and Savage [4]. An RCD has two sets of paral...

2013
Pawan Kumar Lal Bahadur Manjhi Ramesh Lal Rajak

Extruded middle segment of radius with open segmental fracture both bone forearm and dislocation of ipsilateral elbow is a rare injury. A 12-year-old child presented to us within 4 hours following fall from tree. The child's mother was carrying a 12-cm-long extruded soiled segment of radius. The extruded bone was thoroughly washed. The medullary cavity was properly syringed with antiseptic solu...

Journal: :The Journal of bone and joint surgery. British volume 2000
J Pekkarinen A Alho J Lepistö M Ylikoski P Ylinen T Paavilainen

We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction bone grafting, at a median of three years (1 month to 6 years). We employed the cemented Exeter X-Change technique in 36 patients and the uncemented Bi-Metric allografting method in 32. The 37 bone defects were grade 3 or grade 4 on the Endo-Klinik classification. ...

Journal: :Annals of the Academy of Medicine, Singapore 2010
Aziz Nather Vikram David Janelle W H Teng Choon Wei Lee Barry P Pereira

INTRODUCTION This study evaluated the effect of autologous bone marrow derived adult Mesenchymal Stem Cells (MSCs) on the biological healing of weight bearing diaphyseal bone allograft in the tibia of adult rabbits. MATERIALS AND METHODS Forty Adult New Zealand White Rabbits divided into 3 groups (Autograft, Allograft or Allograft impregnated with MSCs) with 12 rabbits in each group were used...

Journal: :annals of military and health science research 0
محمدرضا رفیعی mohamadreza rafiei associate professor of anesthesiology department of aja university of medical sciences, imam reza hospital, tehran, iran مصطفی شهرضایی mostafa shahrezaei associate professor of orthopedicdepartment of aja university of medical sciences, imam reza hospital, tehran, iran محمد افصحی mohamad afsahi assistant professor of anesthesiology department of aja university of medical sciences, imam reza hospital, tehran, iran وحید ضیائی vahid ziae assistant professor of anesthesiology department of najaf abad azad university of medical science سعیدرضا غدیرپور saeedreza ghadirpour general physician ابراهیم حضرتی ebrahim hazrati assistant professor of anesthesiology department of aja university of medical sciences, imam reza hospital, tehran, iran

purpose: according to frequent needs to gastric decompression by nasogastric tube insertion during laparoscopic cholecystectomy, the current comparative study was accomplished through single blind clinical trial considering both the presence and the absence of guide wire insertion. materials and methods: twenty patients were selected for elective surgery of laparoscopic cholecystectomywith gene...

2002
Keun-Taek Oh Chung-Ju Hwang Kyoung-Nam Kim

The purpose of this study was to evaluate mechanical properties of the orthodontic wires according to heat treatment environments and cooling methods. Four types of wires were heat-treated in air, argon and vacuum at 500◦C, for 6 min, and were then either cooled in the furnace or a water bath. Increases in microhardness, maximal strength, yield strength and Young’s modulus of the orthodontic wi...

Journal: :Annals of clinical and laboratory science 1988
J Aronson B Harrison C M Boyd D J Cannon H J Lubansky C Stewart

The animal model developed in the Soviet Union by Ilizarov has been reliably reproduced by us for the mechanical induction of osteogenesis using slow distraction. Our preliminary studies in six adult dogs indicate that this osteogenesis originates from well-structured intramembranous ossification, with rapid maturation to lamellar bone, indistinguishable from surrounding host bone. Mineralizati...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید