نتایج جستجو برای: air kerma strength
تعداد نتایج: 408460 فیلتر نتایج به سال:
PURPOSE To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. METHODS AND MATERIALS One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in ...
Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium co...
OBJECTIVE Different technical and procedural methods have been introduced to develop low radiation dose protocols in neurointerventional examinations. We investigated the feasibility of minimizing radiation exposure dose by simply decreasing the detector dose during cerebral DSA and evaluated the comparative level of image quality using both subjective and objective methods. METHODS In a pros...
Dose calculations to patients undergoing implantation of 125I interstitial brachytherapy sources are affected by two recent changes in low-energy seed dosimetry: (a) implantation of a new primary air-kerma strength standard at the National Institute of Standards and Technology (NIST) on 1 January 1999 and (b) publication of revised dose-rate distributions in AAPM's Task Group 43 Report. The gui...
PURPOSE The clinical use of brachytherapy sources requires the existence of dosimetric data with enough of quality for the proper application of treatments in clinical practice. It has been found that the published data for the low dose rate CSM11 Cs-137 source lacks of smoothness in some regions because the data are too noisy. The purpose of this study was to calculate the dosimetric data for ...
the study of air infiltration into the buildings is important from several perspectives that may be noted to energy and design of hvac systems, indoor air quality and thermal comfort and design of smoke control systems. given the importance of this issue, an experimental and numerical study of air infiltration through conventional doors and windows has been explored in iran. to this end, at fir...
BACKGROUND One goal of increasing awareness of radiation dose is to encourage personal and technical modifications in order to reduce the radiation exposure of patients and staff. OBJECTIVE To analyze the radiation doses incurred during diagnostic cerebral angiography and the angiographic techniques practiced over a 4-year period, in order to demonstrate the effectiveness of implementing radi...
The percutaneous coronary intervention (PCI) procedure is associated with potentially high levels of radiation exposure and therefore increased risk of adverse radiation-induced outcomes, ranging from cataract to malignancy. Frame rate reduction and selective fluoroscopy storage may help reduce radiation exposure. In this study, we evaluated the efficacy of a radiation reduction protocol that u...
The main purpose of this study was to investigate patient dose in the chest (PA/AP/LAT) and skull (PA/AP/LAT) X-ray examinations, as frequent procedures. The study was performed in eight public hospitals of Khuzestan province, Iran. Patient dosimetry was conducted on 567 standard patient X-ray examinations (males: 61.2%, female: 38.2%). Dosimetry protocol in this study was indirect method, acco...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید