نتایج جستجو برای: inclined strut

تعداد نتایج: 12846  

Journal: :Energies 2022

Struts as an important structure in the combustion chamber of hypersonic flight vehicles to inject fuel into main flow face a severe thermal environment. Transpiration cooling is considered potential method provide protection for struts. This paper presents numerical investigation on transpiration strut based Darcy–Forchheimer model and local non-equilibrium analyzes mechanism cooling. A coolan...

Journal: :European heart journal 2016
Tommaso Gori Thomas Jansen Melissa Weissner Nicolas Foin Philip Wenzel Eberhard Schulz Stephane Cook Thomas Münzel

BACKGROUND Peri-stent coronary evaginations may disturb flow and have been proposed as possible risk factor for late stent thrombosis. We describe incidence, predictors, and possible mechanisms of coronary evaginations 12 months after implantation of bioresorbable vascular scaffolds (BVS). METHODS AND RESULTS One hundred and two BVS implanted in 90 patients (age 63 ± 13 years, 71 males, 14 di...

Journal: :Journal of biomechanical engineering 2006
Divakar Rajamohan Rupak K Banerjee Lloyd H Back Ashraf A Ibrahim Milind A Jog

A major consequence of stent implantation is restenosis that occurs due to neointimal formation. This patho-physiologic process of tissue growth may not be completely eliminated. Recent evidence suggests that there are several factors such as geometry and size of vessel, and stent design that alter hemodynamic parameters, including local wall shear stress distributions, all of which influence t...

Journal: :European heart journal 2011
Josep Gomez-Lara Salvatore Brugaletta Roberto Diletti Scot Garg Yoshinobu Onuma Bill D Gogas Robert Jan van Geuns Cécile Dorange Susan Veldhof Richard Rapoza Robert Whitbourn Stephan Windecker Hector M Garcia-Garcia Evelyn Regar Patrick W Serruys

AIMS The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal respons...

Journal: :Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 2014
Jeffrey R Cook Ajay Mhatre Fen Wei Wang Barry F Uretsky

AIMS Optimizing stent deployment is important for both acute- and long-term outcomes. High-pressure balloon inflation is the standard for coronary stent implantation. However, there is no standardized inflation protocol. We hypothesized that prolonged high-pressure balloon inflation until stabilization of inflation pressure is superior to a rapid inflation/deflation sequence for both stent expa...

2004
N. P. Avdelidis D. P. Almond

An investigation has been made of the potential of pulsed transient thermography for identifying the location of fixtures beneath aircraft skins to facilitate accurate automated assembly operations. Experimental studies have been made of 1.6mm thick aluminium skins and both 2mm and 4mm thick carbon fibre reinforced plastic (CFRP) composite skins over both aluminium and composite struts, represe...

Journal: :Journal of the American College of Cardiology 2008
Masamichi Takano Masanori Yamamoto Shigenobu Inami Daisuke Murakami Koji Seimiya Takayoshi Ohba Yoshihiko Seino Kyoichi Mizuno

s w t o t n t b w o the Editor: Presently, occurrence of late stent thrombosis (LST) fter drug-eluting stent implantation is a major clinical concern. lthough LST is an infrequent complication, LST can lead to erious results. A long-term follow-up study revealed recently that ST occurs at a constant rate of 0.6%/year for up to 3 years after rug-eluting stent implantation (1). Regarding patholog...

2017
Bastiaan C. J. Majoor Marleen J. M. Peeters-Boef Michiel A. J. van de Sande Natasha M. Appelman-Dijkstra Neveen A. T. Hamdy P. D. S. Dijkstra

BACKGROUND Fibrous dysplasia of the proximal femur is a progressive, often recurrent condition of bone that can cause skeletal deformity, fractures, and pain [corrected]. Allogeneic cortical strut grafting to minimize the risk of fracture or as part of fracture treatment is a promising treatment option, but evidence is scarce on the intermediate- to long-term results of this procedure and there...

H. Naderpour, M. T. Braz-César R. C. Barros S.M. Khatami

The objective of this review to be submitted in two independent parts, for steel frames and for RC frames, is to compare their structural performance with respect to the proposed N2-method, and so also of the consequent convenience of using pushover methodology for the seismic analysis of these structures. A preliminary investigation is presented on a pushover analysis used for the seismic perf...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید