نتایج جستجو برای: cobas amplicor monitor test

تعداد نتایج: 883872  

Journal: :Journal of clinical microbiology 1998
R Sun J Ku H Jayakar J C Kuo D Brambilla S Herman M Rosenstraus J Spadoro

With the recent introduction of combination therapy, human immunodeficiency virus type 1 (HIV-1) RNA levels in plasma have been dramatically reduced, frequently to below the limit of quantitation (400 copies/ml of plasma) of the AMPLICOR HIV-1 MONITOR Test (Roche Diagnostic Systems). To achieve enhanced sensitivity of the AMPLICOR HIV-1 MONITOR Test, a modified specimen preparation procedure th...

Journal: :The new microbiologica 2006
Aydan Ozkutuk Sevin Kirdar Sevinc Ozden Nuran Esen

Tuberculosis (TB) is one of the major public health problems in the world. Effective control of TB depends on rapid and correct diagnosis and appropriate treatment. The aim of this study was to evaluate the performance of Cobas Amplicor MTB (CA-MTB) test for pulmonary and extrapulmonary specimens isolated in our laboratory. A total of 424 specimens obtained from the suspected TB patients from J...

Journal: :Journal of clinical microbiology 2002
Elyse J Singer H Aaron Aronow Shing-Yi Lee Charles H Hinkin Tadd Lazarus

We evaluated the effects of time, temperature, freezing, and thawing on the cerebrospinal fluid viral load by using the Roche AMPLICOR HIV-1 MONITOR test, version 1.5 (ultrasensitive). While a statistically significant decrease from the baseline was observed at 24 h, but not at 6 or 12 h, and with one freeze-thaw cycle, all changes were within the range of intra-assay variability.

Journal: :Journal of clinical microbiology 1997
H H Kessler B Santner H Rabenau A Berger A Vince C Lewinski B Weber K Pierer D Stuenzner E Marth H W Doerr

The AMPLICOR Enterovirus Test was evaluated with 103 cerebrospinal fluid (CSF) specimens. Twenty-seven CSF specimens were culture positive. With the AMPLICOR test, enterovirus RNA was detected in 34 specimens. Compared with culture, the AMPLICOR test gave a sensitivity of 96.3% and a specificity of 100%. The sensitivity of culture was 79.4% in comparison with the AMPLICOR test.

Journal: :Folia medica 2010
Manabu Abe Corinne Klett Eberhard Wieland Sascha Gille Olfert Landt

BACKGROUND Clinically, both viral load and genotypes have been found to be major predictors of antiviral therapy outcome regarding chronic hepatitis C and they are, under normal circumstances, performed as separate assays. DESIGN AND METHODS In order to improve the diagnostic strategy and subsequently reduce the reagent costs we have developed and established the simultaneous quantification a...

Journal: :Sexually transmitted infections 2000
M H Wilcox M T Reynolds C M Hoy J Brayson

OBJECTIVES Sampling of both the cervix and urine increases the chance of detection of Chlamydia trachomatis compared with sampling either site alone. We determined the effect of combining urine and cervical swab specimens in the clinic setting on the sensitivity of C trachomatis polymerase chain reaction (PCR) testing. METHODS For each of 100 women attending a genitourinary medicine clinic wi...

Journal: :Journal of clinical microbiology 1997
B P Griffith M O Rigsby R B Garner M M Gordon T M Chacko

The Amplicor HIV-1 Monitor test was compared to the nucleic acid sequence-based amplification (Nasba) assay system for the quantitation of human immunodeficiency virus (HIV) RNA in three different types of clinical samples: plasma, serum, and plasma subjected to freeze-and-thaw cycles. Each assay detected HIV RNA in the same 73 (90%) of 81 samples tested, and the quantitative results obtained w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید