نتایج جستجو برای: automated perimetry

تعداد نتایج: 130533  

Journal: :European journal of ophthalmology 2005
S Noval I Contreras G Rebolleda F J Muñoz-Negrete B Ruiz de Zárate

PURPOSE To evaluate and compare the diagnostic ability of frequency doubling technology perimetry (FDT) with standard automated perimetry (SAP) using Humphrey Field Analyser for the detection of visual field defects produced by chiasmal lesions. METHODS Fifteen patients with documented chiasmal disease and previously diagnosed of bitemporal hemianopia with Humphrey perimetry were prospectivel...

Journal: :The British journal of ophthalmology 2002
M C Westcott D F Garway-Heath F W Fitzke D Kamal R A Hitchings

AIM To examine whether high spatial resolution perimetry (HSRP) could identify fine scale scotomata which may not be apparent with conventional perimetry. The HSRP was performed in the nasal field, as this location is a recognised site for the early occurrence of glaucomatous defects. METHOD 16 early glaucoma eyes, 17 glaucoma suspect eyes, and 20 age matched healthy control eyes underwent co...

2009
Italo Giuffrè

BACKGROUND Frequency doubling technology (FDT) perimetry measures contrast sensitivity. The magnocellular component of ganglion cells in human retina is isolated as a whole by the FDT stimulus. The aim of this study is to investigate the role of Humphrey Matrix threshold testing in the detection of early functional retinal impairment in ocular hypertensive patients compared to standard automate...

Journal: :JAMA ophthalmology 2014
Shu Liu Marco Yu Robert N Weinreb Gilda Lai Dennis Shun-Chiu Lam Christopher Kai-Shun Leung

IMPORTANCE While standard automated perimetry (SAP) remains the reference standard for evaluation of visual field (VF) defects in glaucoma, this study demonstrates that frequency-doubling technology (FDT) perimetry is effective in monitoring visual field progression and may detect the onset of visual field defects earlier than SAP. OBJECTIVES To compare detection of the development of VF defe...

2017
Ian C. Murray Antonios Perperidis Lorraine A. Cameron Alice D. McTrusty Harry M. Brash Andrew J. Tatham Pankaj K. Agarwal Brian W. Fleck Robert A. Minns

PURPOSE We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). METHODS A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to monitor eye movement responses to stimul...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید