نتایج جستجو برای: 6 mev electron beam

تعداد نتایج: 1335450  

Journal: :Physical review letters 2011
P McKenna A P L Robinson D Neely M P Desjarlais D C Carroll M N Quinn X H Yuan C M Brenner M Burza M Coury P Gallegos R J Gray K L Lancaster Y T Li X X Lin O Tresca C-G Wahlström

The effect of lattice structure on the transport of energetic (MeV) electrons in solids irradiated by ultraintense laser pulses is investigated using various allotropes of carbon. We observe smooth electron transport in diamond, whereas beam filamentation is observed with less ordered forms of carbon. The highly ordered lattice structure of diamond is shown to result in a transient state of war...

1988
G. Mavrogenes

The 1.25 A, 40 ns electron beam is accelerated in the 200 MeV electron linac. This beam is then focused onto a 3 rom diameter spot at the 7 rom thick (i. e., two radiation length) tungsten target. By the process of multiple nuclear-scattering the target generates the positron particles. These positrons, in general, can have a large diverging angle. The empirical formula for an angular dependenc...

2005
L. R. Prost A. Shemyakin

Fermilab’s 4.3 MeV electron cooler is based on an electrostatic accelerator, which generates a DC electron beam in an energy recovery mode. Effective cooling of the antiprotons in the Recycler requires that the beam remains stable for hours. While short beam interruptions do not deteriorate the performance of the Recycler ring, the beam may provoke full discharges in the accelerator, which sign...

2012
X. Ding L. Shao D. Cline I. Pogorelsky K. Kusche M. Fedurin V. Yakimenko

This first stage experiment is a Proof-of-Principle to support our novel vacuum laser acceleration (VLA) theory, published previously. Simulations show that based on current experimental conditions at the Brookhaven National Laboratory Accelerator Test Facility (ATF), an electron beam with initial energy of 15 MeV can get net energy gain from an intense CO2 laser beam. The difference of electro...

2001
A. Burov A. C. Crawford K. Carlson V. Dudnikov T. Kroc J. Leibfritz M. McGee S. Nagaitsev G. Saewert C. W. Schmidt A. Shemyakin A. Warner

An important part of the Fermilab’s Recycler Electron Cooling (REC) project [1] is a recirculation test which is performed using a 5-MV electrostatic accelerator, a Pelletron, with two tubes and a simplified beam line with one 180-degree bend. The main goal of the test is to demonstrate stable operation of a 4.4-MeV, 0.5-A DC electron beam. The paper describes the set-up and the early experimen...

2010
Collins Yeboah Alex Karotki Dylan Hunt Rick Holly

In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height along applicator and of lateral distance from applicator body. Relative to ce...

Journal: :Physical review letters 2006
D K Johnson D Auerbach I Blumenfeld C D Barnes C E Clayton F J Decker S Deng P Emma M J Hogan C Huang R Ischebeck R Iverson C Joshi T C Katsouleas N Kirby P Krejcik W Lu K A Marsh W B Mori P Muggli C L O'Connell E Oz R H Siemann D Walz M Zhou

Positrons in the energy range of 3-30 MeV, produced by x rays emitted by betatron motion in a plasma wiggler of 28.5 GeV electrons from the SLAC accelerator, have been measured. The extremely high-strength plasma wiggler is an ion column induced by the electron beam as it propagates through and ionizes dense lithium vapor. X rays in the range of 1-50 MeV in a forward cone angle of 0.1 mrad coll...

Journal: :Physical review letters 2012
G Andonian D Stratakis M Babzien S Barber M Fedurin E Hemsing K Kusche P Muggli B O'Shea X Wei O Williams V Yakimenko J B Rosenzweig

We report first evidence of wakefield acceleration of a relativistic electron beam in a dielectric-lined slab-symmetric structure. The high energy tail of a ∼60  MeV electron beam was accelerated by ∼150  keV in a 2 cm-long, slab-symmetric SiO2 waveguide, with the acceleration or deceleration clearly visible due to the use of a beam with a bifurcated longitudinal distribution that serves to app...

2000
M. E. R. Poli A. S. Todo L. L. Campos

The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the cutaneous T-cell lymphoma (mycosis fungoides). The cure may be obtained in 10% to 40% of the cases [13]. To irradiate all skin in an appropriate time of the machine, in most times, are used large electron fields with treatment distances about 3 meters. The original ...

Journal: :Philosophical transactions. Series A, Mathematical, physical, and engineering sciences 2009
Ondrej L Krivanek Jonathan P Ursin Neil J Bacon George J Corbin Niklas Dellby Petr Hrncirik Matthew F Murfitt Christopher S Own Zoltan S Szilagyi

An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید