نتایج جستجو برای: biocompatibility testing

تعداد نتایج: 346246  

2011
René Olivares-Navarrete Jhon Jairo Olaya Claudia Ramírez Sandra Elizabeth Rodil

Niobium coatings deposited by magnetron sputtering were evaluated as a possible surface modification for stainless steel (SS) substrates in biomedical implants. The Nb coatings were deposited on 15 mm diameter stainless steel substrates having an average surface roughness of 2 μm. To evaluate the biocompatibility of the coatings three different in vitro tests, using human alveolar bone derived ...

2017
Yu-Jin Zeng Sheng-Chen Twan Kuan-Wen Wang Her-Hsiung Huang Yen-Bin Hsu Chien-Ying Wang Ming-Ying Lan Sheng-Wei Lee

This study first investigates the biocompatibility of self-organized TaO x nanotube arrays with different nanotube diameters fabricated by electrochemical anodization. All as-anodized TaO x nanotubes were identified to be an amorphous phase. The transition in surface wettability with TaO x nanotube diameters can be explained based on Wenzel's model in terms of geometric roughness. In vitro bioc...

2016
Jixing Lin Sertan Ozan Yuncang Li Dehai Ping Xian Tong Guangyu Li Cuie Wen

Titanium alloys are receiving increasing research interest for the development of metallic stent materials due to their excellent biocompatibility, corrosion resistance, non-magnetism and radiopacity. In this study, a new series of Ti-Ta-Hf-Zr (TTHZ) alloys including Ti-37Ta-26Hf-13Zr, Ti-40Ta-22Hf-11.7Zr and Ti-45Ta-18.4Hf-10Zr (wt.%) were designed using the d-electron theory combined with ele...

Journal: :Advances in wound care 2014
Hans Machula Burt Ensley Robert Kellar

Objective: To evaluate the physiological effects of electrospun tropoelastin scaffolds as therapeutic adipose-derived stem cell (ADSC) delivery vehicles for the treatment of full-thickness dermal wounds. Approach: Using the process of electrospinning, several prototype microfiber scaffolds were created with tropoelastin. Initial testing of scaffold biocompatibility was performed in vitro throug...

Journal: :Journal of neuroscience methods 2009
You-Yin Chen Hsin-Yi Lai Sheng-Huang Lin Chien-Wen Cho Wen-Hung Chao Chia-Hsin Liao Siny Tsang Yi-Fan Chen Si-Yue Lin

The design and testing of a new microelectrode array, the NCTU (National Chiao Tung University) probe, was presented. Evaluation results showed it has good biocompatibility, high signal-to-noise ratio (SNR: the root mean square of background noise to the average peak-to-peak amplitude of spikes) during chronic neural recordings, and high reusability for electrolytic lesions. The probe was a fle...

Journal: :Journal of biomaterials applications 2016
Karin Lukas Ulrich Thomas André Gessner Daniel Wehner Thomas Schmid Christof Schmid Karla Lehle

Medical devices made of polycarbonaturethane (PCU) combine excellent mechanical properties and little biological degradation, but restricted hemocompatibility. Modifications of PCU might reduce platelet adhesion and promote stable endothelialization. PCU was modified using gas plasma treatment, binding of hydrogels, and coupling of cell-active molecules (modified heparin, anti-thrombin III (ATI...

2011
Azhang Hamlekhan Fathollah Moztarzadeh Masoud Mozafari Mahmoud Azami Nader Nezafati

In this research, new bioactive nanocomposite scaffolds were successfully developed using poly(ε-caprolactone) (PCL), cross-linked gelatin and nanoparticles of hydroxyapatite (HAp) after testing different solvents and methods. First, HAp powder was synthesized via a chemical precipitation technique and characterized. Then, the nanocomposites were prepared through layer solvent casting combined ...

2015
Fengzhen Liu Yunhua Wang Keyi Li Licheng Jiang Xiumei Wang Xin Shao Bin Zhang Fuzhai Cui

Graphene oxide (GO)/ultrahigh-molecular-weight polyethylene (UHMWPE) composites were successfully fabricated through the mechanical ball milling technology and processed according to the hot pressing method. The fractured microstructure features and mechanical properties of the GO/UHMWPE composites were investigated by Scanning electron microscope (SEM) and universal testing machine, respective...

Journal: :dental research journal 0

dental materials that are used in dentistry should be harmless to oral tissues, so they should not contain any leachable toxic and diffusible substances that can cause some side effects. reports about probable biologic hazards, in relation to dental resins, have increased interest to this topic in dentists. the present paper reviews the articles published about biocompatibility of resin-restora...

Journal: :Journal of orthopaedic surgery 2006
A Krisanapiboon B Buranapanitkit K Oungbho

PURPOSE To investigate the biocompatibility of hydroxyapatite composite (hydroxyapatite, plaster of Paris, and chitosan) impregnated with gentamicin, fosfomycin, imipenem, or amphotericin B. METHODS The interactions of the extract from each drug against osteoblast were tested using the methylthiotetrazole test. RESULTS Extracts from all drugs showed good biocompatibility at concentrations v...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید