نتایج جستجو برای: beam gantry

تعداد نتایج: 114050  

2015
Sara L. Hackett Benjamin Davis Andrew Nixon Ruth Wyatt

Constancy checks of a well-type ionization chamber should be performed regularly as part of a quality assurance regime. The goal of this work was to test the feasibility of using a linear accelerator and an orthovoltage unit to check the constancy of a well-type chamber's response to an external radiation source. The reproducibility, linearity with dose, variation with dose-rate, and variation ...

2014
So-Yeon Park Beom Seok Ahn Jong Min Park Sung-Joon Ye Il han Kim Jung-in Kim

BACKGROUND In this study, dosimetric aspects of TSEI consisting of a 4 MeV beam with no spoiler were investigated in comparison to a nominal 6 MeV beam with spoiler, and the potential for clinical applications was evaluated. METHODS The TSEI technique is based on the Stanford technique, which utilizes a beam configuration of six-dual fields. MOSFETs were used to measure the optimal gantry ang...

Journal: :Journal of Nepali Physical Society 2022

Daily morning quality assurance (QA) for all available beams using conventional phantom measures only output and beam quality. PTW QUICKCHECKwebline (PTW QCw) is a compact movable light-weight dosimetry equipment used daily QA, capable of measuring flatness, symmetry, constancy given in single exposure. The purpose this study was to analyze monitor the medical linear accelerator QCw assess over...

2011
Zhihui Hu Jianrong Dai Liang Li Yin Cao Yixin Song Guishan Fu

The purpose of this study was to evaluate beam attenuation by treatment couch and build a treatment couch model in TPS to check for beam-couch intersection at the planning stage and deal with beam attenuation by treatment couch in dose calculation. In this study, a standard treatment couch, Siemens ZXT couch, has been incorporated into Pinnacle3 8.0 TPS, based on an existing TPS tool, model-bas...

2015
Tiezhi Zhang Joshua T. Dilworth Ovidiu Marina Peter Chen Lisa Benedetti Qiang Liu

The purpose of this study was to introduce a three-field monoisocentric inverse treatment planning method without half-beam blocks for breast cancer radiation treatments. Three-field monoisocentric breast treatment planning with half-beam blocks limits the tangential field length to 20 cm. A dual-isocenter approach accommodates patients with larger breasts, but prolongs treatment time and may i...

Journal: :Physics in medicine and biology 2016
M Vidal L De Marzi H Szymanowski L Guinement C Nauraye E Hierso N Freud R Ferrand P François D Sarrut

Collimators are used as lateral beam shaping devices in proton therapy with passive scattering beam lines. The dose contamination due to collimator scattering can be as high as 10% of the maximum dose and influences calculation of the output factor or monitor units (MU). To date, commercial treatment planning systems generally use a zero-thickness collimator approximation ignoring edge scatteri...

2007
Shuai Leng Tingliang Zhuang Brian E. Nett Guang-Hong Chen

Guang-Hong Chen University of Wisconsin–Madison Department of Medical Physics Madison, Wisconsin 53704 and University of Wisconsin–Madison Department of Radiology Madison, Wisconsin 53792 E-mail: [email protected] Abstract. We present a cone-beam image reconstruction algorithm for helical CT scanning with a tilted gantry and N-PI data acquisition. When the gantry is tilted, the effective source t...

Journal: :Concurrent Engineering: R&A 2016
S. R. Besharati V. Dabbagh H. Amini Ahmed A. D. Sarhan J. Akbari M. Hamdi Zhi Chao Ong

In this investigation, the multi-objective selection and optimization of a gantry machine tool is achieved by analytic hierarchy process, multi-objective genetic algorithm, and Pareto-Edgeworth-Grierson–multi-criteria decision-making method. The objectives include maximum static deformation, the first four natural frequencies, mass, and fabrication cost of the gantry. Further structural optimiz...

2005
Young Jin Lee Jin Ho Suh Jin Woo Lee Suk Gyu Lee Kwon Soon Lee

This article presents the design system for high efficiency gantry crane system using elevator and conveyor system. The basic concept for the proposed gantry crane system can be used with modification of the classical gantry crane instead of changing lots of them. However, the proposed crane system can reduce the cycle time more than the classical gantry crane. The high efficiency gantry crane ...

Journal: :Physics in medicine and biology 2014
Sjoerd Crijns Bas Raaymakers

Recently, the MRI-linac prototype at UMC Utrecht was upgraded with a ring-based gantry, where all linac components are mounted on a ring around the MR scanner. Although adaptations have been made to both linac and MR magnets in order to account for mutual magnetic interference, interference problems cannot be ruled out completely. Therefore, in this paper the impact of gantry position dependent...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید