نتایج جستجو برای: overvoltage protection

تعداد نتایج: 180416  

Journal: :Applied sciences 2021

Lightning-induced voltages are one of the main causes shutdown in distribution lines. In this work, attention is focused on effects wideband modeling electric grounding overvoltage calculation along insulator strings due to indirect lightning strikes. This study done directly time-domain with being represented an equivalent circuit accounting for its dynamics. Results show that adoption commonl...

Journal: :Journal of physics 2023

Abstract The simulation models of the 500kV gas-insulated transmission lines (GIL) and substation (GIS) systems in a realistic nuclear plant are presented paper. Very Fast Transient Overvoltage (VFTO) which is generated during switching operations, analyzed. Some affecting factors on level VFTO investigated. These location power source, entrance capacitance potential transformer (PT), capacitiv...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی امیرکبیر(پلی تکنیک تهران) - دانشکده مهندسی برق 1386

طرح های حفاظتی خاص (sps)، طرح هایی هستند که با تشخیص شرایط خاص و غیرمعمول در شبکه که باعث ایجاد فشارهایی بر شبکه قدرت می شوند، وارد عمل شده و بر اساس یک سری عملکردهای از پیش تعیین شده این شرایط خاص را کنترل می کنند. در نتیجه sps ها می توانند موجب بهبود عملکرد، افزایش ظرفیت انتقال و افزایش امنیت شبکه در مقابل اغتشاشات شدید شوند. با این حال اعتماد بیش از حد به sps ممکن است بسیار خطرناک باشد. زیرا...

Journal: :نشریه دانشکده فنی 0
حسین محسنی فرامرز رهبر

usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...

Journal: :the modares journal of electrical engineering 2011
mohammad arasteh abdoreza rahmati seyed adib abrishamifar shahrokh farhangi

this paper gives a detailed analysis of direct torque control (dtc) strategy in a five-level drive and proposes a 24-sector switching table. the overvoltage problem due to high dv/dt is reduced compared to the 12-sector dtc. using all vectors leads to better flexibility and reduces speed oscillations. simulation and experimental results for a 3kva prototype confirm the proposed solutions. a tms...

2006
Jacques Schonek

«Cahiers Techniques» is a collection of documents intended for engineers and technicians, people in the industry who are looking for more in-depth information in order to complement that given in product catalogues. Furthermore, these «Cahiers Techniques» are often considered as helpful «tools» for training courses. They provide knowledge on new technical and technological developments in the e...

Journal: :IEEE Transactions on Electromagnetic Compatibility 2023

Nowadays, plenty of sensitive electronic devices are installed in secondary circuits substations. When lightning strikes a substation and transmission line, currents flow into the grounding structure through shield wires surge arresters primary circuit, overvoltages induced on control cables circuit owing to effect transient ground potential rises electromagnetic coupling. Shielded one counterm...

Journal: :Iet Renewable Power Generation 2023

Indirect lightning strikes hitting near photovoltaic installations are much more frequent than direct hits, and can generate overvoltage in their electric circuitry. The authors developed a method to estimate the induced on single modules. Using model of whole array also including Inter-Module Coupling Mechanisms (IMCMs), new approach full arrays is presented this paper. procedure first estimat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید