PURPOSE To compare intraocular lens (IOL) power calculation and refractive outcome between patients who underwent laser refractive cataract surgery with a femtosecond laser and those with conventional cataract surgery. METHODS In this prospective study, 77 eyes from 77 patients underwent laser refractive cataract surgery (laser group; Alcon LenSx femtosecond laser), and conventional cataract ...
PURPOSE This study aimed to assess the value of intraoperative aberrometry (IA) in determining the intraocular lens (IOL) sphere power in eyes with no previous ocular surgery. PATIENTS AND METHODS We conducted a retrospective review of patients who underwent uncomplicated cataract surgery where standard preoperative (Preop) measurements and IA were performed. Calculated IOL sphere powers and ...
Dear Sir, This letter is to alert about the danger of carrying out biometric calculations for the intraocular lens without being aware that the patient may be using a contact lens. This warning is valid even when the highest precision research technology is being utilised. At present, errors in the calculation of the intraocular lens (IOL) are the most frequent cause of lens exchanges as well a...
PURPOSE To describe the different formulas that try to overcome the problem of calculating the intraocular lens (IOL) power in patients that underwent corneal refractive surgery (CRS). METHODS A Pubmed literature search review of all published articles, on keyword associated with IOL power calculation and corneal refractive surgery, as well as the reference lists of retrieved articles, was pe...
PURPOSE To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING Private practice, Lynwood, California, USA. METHODS The predicted IOL power was calculated in each case. Also calculated were the mean arith...
PURPOSE To evaluate the accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment. METHODS Retrospective case review of 100 consecutive eyes that underwent phacovitrectomy for rhegmatogenous retinal detachment. Axial lengths were measured using optical biometry and/or ultrasound A-scan. Achieved and predicted refraction were compared to...