Radiologic studies of the nasolacrimal system following instillation of various opaque media have been found to be of value in patients with epiphora. However, there are certain disadvantages with these methods. Extravasation of the oily opaque media into the surrounding tissues may subsequently result in the development of pseudopolycystic sacs. The use of too highly concentrated solutions of ...
UNLABELLED (99m)Tc-sestamibi dual-phase scintigraphy is currently established for parathyroid localization. However, the imaging technique is not standardized, and the role of the pinhole collimator, especially, is not fully recognized in the imaging protocol. The aim of this study was to check whether the use of a pinhole collimator in parathyroid scintigraphy would enhance lesion detectabilit...
More and more camera concepts are being investigated to try and seize the opportunity of instantaneous range verification of proton therapy treatments offered by prompt gammas emitted along the proton tracks. Focusing on one-dimensional imaging with a passive collimator, the present study experimentally compared in combination with the first, clinically compatible, dedicated camera device the p...
Events in a sequence may each be evaluated as good or bad. We propose that such good-bad evaluations evoke emotional responses that change current mood. A model of recurrent updating of current mood is developed and compared to a model of how a sequence of events evoking emotional responses is evaluated retrospectively. In Experiment 1, 149 undergraduates are presented sequences of lottery outc...
UNLABELLED The Society of Nuclear Medicine (SNM) published procedure guidelines for thyroid imaging in 1999. We wished to determine how many clinics performing thyroid imaging follow the guidelines and to what extent. Of particular interest to us was the choice of collimator. METHODS We developed a 10-question survey to obtain information on how hospitals perform thyroid imaging. The question...
We evaluation basic characteristics of a compact type semiconductor gamma camera (eZ-SCOPE AN) of Cadmium Zinc Telluride (CdZnTe). This new compact gamma camera has 256 semiconductors representing the same number of pixels. Each semiconductor is 2 mm square and is located in 16 lines and rows on the surface of the detector. The specific performance characteristics were evaluated in the study re...
PURPOSE Investigation of a reduced source to target distance to improve organ at risk sparing during stereotactic irradiation (STX). METHODS The authors present a planning study with perfectly target-volume adapted collimator compared with multi-leaf collimator (MLC) at reduced source to virtual isocentre distance (SVID) in contrast to normal source to isocentre distance (SID) for stereotacti...
In order to achieve a thermal neutron beam for neutron radiography applications, a new neutron collimator has been designed, installed and characterized at Tehran Research Reactor (TRR). TRR is a 5 MW, open pool and light water coolant reactor with seven beam tubes. Neutron collimator that is an important part of neutron radiography system was installed in the six inch E beam tube. Collimator d...
introduction: multileaf collimator (mlc) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. the purpose of this research was ...