Abstract: This paper proposes a novel protection method for single line-to-ground (SLG) faults in ungrounded low-inertia microgrids. The proposed method includes microgrid interface protection and unit protection. The microgrid interface protection is based on the difference between the zero-sequence voltage angle and the zero-sequence current angle at the microgrid interconnection transformer ...
259 Lines are protected by overcurrent-, distance-, or pilot-relaying equipment, depending on the requirements. Overcurrent relaying is the simplest and cheapest, the most difficult to apply, and the quickest to need readjustment or even replacement as a system changes. It is generally used for phaseand ground-fault protection on station-service and distribution circuits in electric utility and...
Precise detection and localization of faults in power transformer windings for ultimate protection is the key issue. The insulation quality in windings majorly determines the enduring transformers function. Achieving as accurate and efficient detection method of partial discharge (PD) in transformer windings is challenging. The occurrence of PD being primarily responsible for the transformers f...
Energization of a transformer results in sudden flow of current which is an effect of core magnetization. This current will be dominated by the presence of second harmonic, which in turn is used to segregate fault and inrush current, thus guaranteeing proper operation of the relay. This additional security in the relay sometimes obstructs or delays differential protection in a specific scenario...
DC bias current flowing into the neutral point of power transformer will seriously affect the normal operation of AC power system. In this paper, exciting current, harmonic component of the excitation current, magnetic flux density and noise of transformer were analyzed when the transformer is in the no-load operation state based on field-circuit coupled method. Through the calculation and anal...
In many text books and papers such as [1]-[5], it is possible to find descriptions about shunt fault calculations and about the influence of the three-phase transformer connection Dyn on the fault currents distribution through distribution transformers. In [6] is described a method for digitally simulating a three-phase power system which is subjected to a fault at one location with blown fuse ...
Transformer tank vibration has been used for the condition monitoring and fault diagnosis of power transformers, as well as for the evaluation of radiated sound power from such power transformers. In both applications, seeking a correlation between transformer tank vibration and the vibration of the transformer windings and core becomes a challenge for fault identification and noise control at ...
A COMPREHENSIVE MODEL FOR THE POWER TRANSFORMER DIGITAL DIFFERENTIAL PROTECTION FUNCTIONING RESEARCH
The three-phase power transformer in the transmission or distribution substations represents one of essential devices on electric networks. Losing this devise cause a disconnection utility to large number electrical loads. robust protection system must be designed protect device during abnormal operations. A complete for poly-phase Karbala networks (East substation) is modeled and simulated, ad...
The paper analyzes the large power transformer unit regimes, indicating the criteria for the management of the voltage operating conditions, as well as the change in the operating conditions with the load connected to the secondary winding of the transformer unit. Further, the paper presents the software application for the evaluation of the transformer unit operation under different conditions...