نتایج جستجو برای: ultc transformer

تعداد نتایج: 11492  

2009
Anjali Chatterjee Nirmal Kumar Roy

Economically transformers constitute one of the largest investments in a Power system. For this reason, transformer condition assessment and management is a high priority task. If a transformer fails, it would have a significant negative impact on revenue and service reliability. Monitoring the state of health of power transformers has traditionally been carried out using laboratory Dissolved G...

2015
Sherif S. M. Ghoneim Ibrahim B. Taha

Transformer is the main important equipment in electrical power system. Early stage detection of the transformer faults has great economic significance because it considered expensive equipment and it helps to maintain the continuous operation of the electrical power system. Transformer oil is used for two main purposes, one for insulating liquid and the other for cooling. Some physicalchemical...

2016
Krupa Rajendra Shah K. Ragavan

Certain level of mechanical deformations in winding does not hamper the normal performance of power transformer. However, such incipient deformations if unattended could result in permanent failure of transformer. To this end, an approach is proposed to assess the severity of mechanical deformations in transformer winding. These deformations get reflected as changes in its high frequency behavi...

2012
M. Srinivasan A. Krishnan

The Hot Spot Temperature (HST) value depends on the ambient temperature, the rise in the top oil temperature (TOT) over the ambient temperature, and the rise in the winding HST over the top oil temperature. In this paper a new semi-physical model comprising of the environmental variables for the estimation of HST and loss of insulation life in transformer is proposed. The winding hot-spot tempe...

2017
Zhongyong Zhao Chao Tang Qu Zhou Lingna Xu Yingang Gui Chenguo Yao

A transformer is the most valuable and expensive property for power utility, thus ensuring its reliable operation is a major task for both operators and researchers. Online impulse frequency response analysis has proven to be a promising technique for detecting transformer internal winding mechanical deformation faults when a power transformer is in service. However, as so far, there is still n...

2015
Peng Wang Hong Jiang Xu Liu Jizhong Han

Within the past decade, there have been a number of parallel programming models developed for data-intensive (i.e., big data) applications. Typically, each model has its own strengths in performance or programmability for some kinds of applications but limitations for others. As a result, multiple programming models are often combined in a complimentary manner to exploit their merits and hide t...

2009
Piush Verma Yog Raj Sood Jashandeep Singh

Transformer is one of the most important and costly apparatus in a power system. The reliable and efficient fault free operation of transformer has a decisive role in the availability of electricity supply. In recent years, there has been growing interest in the condition assessment of transformer insulation. In this paper we concerned about the condition monitoring of transformer, benefit of c...

2016
Jing Zheng Jie Pan Hai Huang

Transformer tank vibration has been used for the condition monitoring and fault diagnosis of power transformers, as well as for the evaluation of radiated sound power from such power transformers. In both applications, seeking a correlation between transformer tank vibration and the vibration of the transformer windings and core becomes a challenge for fault identification and noise control at ...

2013
M. Banupriya R. Punitha B. Vijayalakshmi C. Ram Kumar

This paper proposes a wireless ZigBee technology to monitor the parameters of the transformer. The transformer parameters such as voltage, current, power factor and temperature can be monitored through wireless ZigBee technology. Embedded Ethernet is used to develop client and server applications. Acquisition of voltages, currents, temperatures, active and reactive power, controlling the switch...

2013
Mohd Zaifulrizal ZAINOL Nasrudin ABD. RAHIM Jeyraj SELVARAJ

A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer. This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Finally, the experimental set up is built to transfer power of 300 W over the different gap var...

نمودار تعداد نتایج جستجو در هر سال