نتایج جستجو برای: inclined cantilever

تعداد نتایج: 15881  

2017
Myung-Sic Chae Jinsik Kim Yong Kyoung Yoo Jeong Hoon Lee Tae Geun Kim Kyo Seon Hwang

A microsized slit-embedded cantilever sensor (slit cantilever) was fabricated and evaluated as a biosensing platform in a liquid environment. In order to minimize the degradation caused by viscous damping, a 300 × 100 µm² (length × width) sized cantilever was released by a 5 µm gap-surrounding and vibrated by an internal piezoelectric-driven self-actuator. Owing to the structure, when the singl...

Journal: :Journal of structural biology 2017
Devin T Edwards Thomas T Perkins

Atomic force microscopy (AFM)-based single-molecule force spectroscopy (SMFS) enables a wide array of studies, from measuring the strength of a ligand-receptor bond to elucidating the complex folding pathway of individual membrane proteins. Such SMFS studies and, more generally, the diverse applications of AFM across biophysics and nanotechnology are improved by enhancing data quality via impro...

2015
Zeno Schumacher Yoichi Miyahara Laure Aeschimann Peter Grütter

Optical beam deflection systems are widely used in cantilever based atomic force microscopy (AFM). Most commercial cantilevers have a reflective metal coating on the detector side to increase the reflectivity in order to achieve a high signal on the photodiode. Although the reflective coating is usually much thinner than the cantilever, it can still significantly contribute to the damping of th...

Journal: :Proceedings of the National Academy of Sciences of the United States of America 2009
Eric W Moore SangGap Lee Steven A Hickman Sarah J Wright Lee E Harrell Peter P Borbat Jack H Freed John A Marohn

We report an approach that extends the applicability of ultrasensitive force-gradient detection of magnetic resonance to samples with spin-lattice relaxation times (T (1)) as short as a single cantilever period. To demonstrate the generality of the approach, which relies on detecting either cantilever frequency or phase, we used it to detect electron spin resonance from a T (1) = 1 ms nitroxide...

Journal: :The Review of scientific instruments 2013
Huan Wang J C Fenton O Chiatti P A Warburton

Nanoscale mechanical resonators are highly sensitive devices and, therefore, for application as highly sensitive mass balances, they are potentially superior to micromachined cantilevers. The absolute measurement of nanoscale displacements of such resonators remains a challenge, however, since the optical signal reflected from a cantilever whose dimensions are sub-wavelength is at best very wea...

2002
James Blanchard Hui Li Amit Lal

A radioisotope-powered, self-oscillating cantilever beam has been developed for small scale applications. A thin beam is placed within a short distance from a radioisotope source and as the charged particles from the source are collected on the beam, it is attracted towards the source. As it contacts the source, the beam is discharged and returns to it's initial position. The period of oscillat...

2008
H. Sadeghian J. F. L. Goosen A. Bossche F. van Keulen

Submicron cantilever structures have been demonstrated to be extremely versatile sensors and have potential applications in physics, chemistry and biology. The basic principle in submicron cantilever sensors is the measurement of the resonance frequency shift due to the added mass of the molecules bound to the cantilever surface. This paper presents a theoretical model to predict the resonance ...

Journal: :Automation in Construction 2021

Important developments in additive manufacturing with concrete have been achieved the past decades. Yet, printed components usually do not comply building standards or basic reliability principles, and are commonly used as load-bearing components. A gap between research practice exists despite several attempts, off-the-shelf commercial solutions for reinforcement of 3D structural seem always ex...

2008
B. Zeyen B. Pittenger K. Virwani K. L. Turner

A novel preamplifying cantilever (PCL) design for scanning probe microscopes (SPM) that is capable of mechanically amplifying specimen movements is presented. The sample motions in both out-of-plane and in-plane directions are amplified by the PCL. The spatial resolution of the cantilever is in the nanometer scale and is comparable with existing SPM cantilevers. Some of the proposed application...

Journal: :journal of dentistry, tehran university of medical sciences 0
a. fazel associate professor, department of prosthodontics, school of dentistry, tehran university of medical m. rismanchian associate professor, department of prosthodontics, school of dentistry, isfahan university of medica

objective: the aim of this study was to evaluate and compare the status of supporting tissue around implant-supported fixed partial denture with or without cantilever clinically and radiographically during a four-year period. materials and methods: one hundred and fifty nine patients who were treated by 482 implants supported fixed partial prosthesis with and without cantilever after at least f...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید