نتایج جستجو برای: ebt3 gafchromic film

تعداد نتایج: 91000  

بخشنده, محسن, عابدی فیروزجاه, رزاق, نیک فرجام, ابوالفضل,

Introdution: In advanced radiotherapy techniques such as intensity modulated radiation therapy (IMRT), the quality assurance (QA) is essential. This study aimed to compare the performance between GafchromicTM EBT3 film and Delta4® phantom (2D and 3D) in heterogeneous chest phantom using IMRT technique. Methods: In this experimental study, two IMRT plans (A and B) were prepared for radiothe...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2006
Tsang Cheung Martin J Butson Peter K N Yu

The EBT Gafchromic radiochromic film is a relatively new product designed specifically for dosimetry in radiation therapy. Due to the weak dependence of its response on the photon energy (variations are below 10% in the 50 kVp-10 MVp range), the film is ideal for dosimetry when the photon energy spectrum may be changing or unknown. In order to convert a map of optical densities into a map of ab...

H.Z. Wang, J. Bao, J.H. Zhu, L. Chen, Y. Gao, Z.F. Fei, Z.T. Hu,

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

2014
Volker Rudat Alaa Nour Abdul Aziz Alaradi Adel Mohamed Saleh Altuwaijri

PURPOSE The purpose of this study was to compare the surface dose of 7-field IMRT (7 F-IMRT), tangential beam IMRT (TB-IMRT), and tangential beam 3D-CRT (3D-CRT) of breast cancer patients receiving adjuvant radiotherapy by means of in vivo GafChromic film dosimetry. MATERIAL AND METHODS Breast cancer patients receiving adjuvant radiotherapy of the whole breast or the chest wall were eligible ...

2007
Robert Y.L. Chu Tin Lam Yongguang Liang

The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and th...

Ahmad Mostaar, Mohammad Houshyari Saeede Amiri

Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...

2012
Chris J. Mart Howard R. Elson Michael A. S. Lamba

Some of the lowest voltages used in radiotherapy are termed Grenz and superficial X-rays of ~ 20 and ~ 100 kVp, respectively. Dosimetrically, the surface doses from these beams are calculated with the use of a free in-air air kerma measurement combined with a backscatter factor and the appropriate ratio of mass energy absorption coefficients from the measurement material to water. Alternative t...

Journal: :Physics in medicine and biology 2005
Martin J Butson Tsang Cheung Peter K N Yu

Gafchromic XR type-R radiochromic film is a relatively new product designed for use at clinical diagnostic x-ray energies both qualitatively and quantitatively. This short note investigates the energy response characteristics of this high-sensitivity radiochromic film for both diagnostic and therapeutic x-ray energies. Results are also compared to conventional silver halide x-ray film for energ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید