نتایج جستجو برای: artisan iol
تعداد نتایج: 2687 فیلتر نتایج به سال:
Background: Opacification of ophthalmic devices has been previously reported in silicone scleral buckle, Molteno implant, and intraocular lens opacification. However, there is no report on polymethyl methacrylate (PMMA) intraocular lens (IOL) calcification. Objective: Report the clinical feature, histopathologic and spectrophotometer analysis of opacified three-piece PMMA IOL. Method: A 60-year...
We experienced a case of intraocular lens (IOL) luxation with the capsular bag after vitrectomy. The case was a 66-year-old female in whom an IOL was implanted one year after surgery for giant tear retinal detachment using silicone oil. Four years after the implantation surgery, the patient suffered subluxation of the IOL with the capsular bag. Examinations of the luxated IOL with the capsular ...
PURPOSE To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results. SETTING Private practice, Jackson, Michigan, USA. DESIGN Comparative case series. METHODS This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism ...
PURPOSE To assess the safety and outcome of single-piece posterior chamber intraocular lens (PC-IOL) implantation in the ciliary sulcus following posterior capsular rupture during cataract surgery. METHODS Patients with posterior capsular rupture during cataract surgery with a single-piece acrylic IOL implanted into the ciliary sulcus were studied. Complete ocular examinations were performed ...
PURPOSE Intraocular lymphoma (IOL) frequently coexists with primary central nervous system lymphoma(PCNSL). We sought to determine the efficacy of high-dose methotrexate (MTX) alone in patients with IOL. We also sought to determine whether micromolar levels of MTX could be achieved in the aqueous and vitreous humor of the eye after i.v. administration of the drug. EXPERIMENTAL DESIGN Nine pat...
PURPOSE To evaluate the benefit of various surgical methods to address pseudophakic negative dysphotopsia. SETTING Private practice, Los Angeles, California, USA. DESIGN Interventional case series. METHODS The following 4 surgical methods were used to treat negative dysphotopsia: secondary piggyback intraocular lens (IOL) implantation, reverse optic capture, in-the-bag IOL exchange, and i...
To investigate if the surface modification of intraocular lens (IOL) is efficient in the prevention of posterior capsular opacification (PCO), the acrylic surface of intraocular lens (Acrysof) was polymerized with polyethylene glycol (PEG-IOL). The human lens epithelial cells (1 x 10(4) cells/mL) were inoculated on PEG grafted or unmodified acrylic lenses for the control. The adherent cells on ...
Objective: The objectives of this review were to identify the predictive factors of induction of labor (IOL) failure or success as well as to highlight the current heterogeneity regarding the definition and diagnosis of failed IOL. Materials and Methods: Only studies in which the main or secondary outcome was failed IOL, defined as not entering the active phase of labor after 24 h of prostaglan...
BACKGROUND The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). METHODS Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Car...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید