نتایج جستجو برای: air kerma strength

تعداد نتایج: 408460  

2014
Yingjie Xu Yuan Tian Jianrong Dai

A radioactive source is usually replaced and disposed after being used for a certain amount of time (usually a half-life). In this study, a simple method is proposed to prolong its service life. Instead of replacing the used source with a new source of full activity, a new source of less activity is added in the source holder in front of the used one, so that the total activity of two sources i...

Journal: :Korean circulation journal 2015
Jongmin Hwang Soo Yong Lee Min Ku Chon Sang Hyun Lee Ki Won Hwang Jeong Su Kim Yong Hyun Park June Hong Kim Kook Jin Chun

BACKGROUND AND OBJECTIVES Coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease. However, exposure to ionizing radiation delivered during CAG has various negative biological effects on humans. In this study, there was an evaluation of whether fluorography resulted in decreased radiation exposure, as compared with cineangiography. SUBJECTS AND METHODS Fifty-fiv...

2013
J. H. Lee J. N. Wang T. T. Huang S. H. Su B. J. Chang C. H. Su S. M. Hsu

The aim of the present study was to estimate the wall effect of the self-made spherical graphite-walled cavity chamber with the Monte Carlo method for establishing the air-kerma primary standard of high-dose-rate (HDR) ¹⁹²Ir brachytherapy sources at the Institute of Nuclear Energy Research (INER, Taiwan). The Monte Carlo method established in this paper was also employed to respectively simulat...

2011
Sunil Dutt Sharma Sudhir Kumar P. Srinivasan G. Chourasiya

A guarded cylindrical graphite ionization chamber of nominal volume 1000 cm3 was designed and fabricated for use as a reference standard for low-dose rate 137Cs brachytherapy sources. The air kerma calibration coefficient (N(K)) of this ionization chamber was estimated analytically using Burlin's general cavity theory, as well as by the Monte Carlo simulation and validated experimentally using ...

Journal: :Arrhythmia & electrophysiology review 2013
Xianxian Jiang Lukas Rc Dekker

To assess patient radiation during catheter ablation procedures and operator differences. From 84 patients (51 males, age 63 ± 10 years) undergoing complex catheter ablation by three experienced operators we collected: body mass index (BMI), procedure type and time, fluoroscopy time, dose area product (DAP), air kerma and X-ray system setting (cine, collimation and angiographic imaging angle). ...

2013
Marzieh Anjomrouz Mahdi Sadeghi Asghar Haddadi

Higher initial dose rate and simplifying HDR room treatment of 169Yb element among other brachytherapy sources has led to investigating its feasibility as high-dose-rate seed. In this work, Monte Carlo calculation was performed to obtain dosimetric parameters of 169Yb, Model M42 source at different radial distances according to AAPM TG-43U1 and HEBD Report about HDR sources in both air vacuum a...

2014
Kenichi Tanaka Satoru Endo Kunihiko Tateoka Osamu Asanuma Masakazu Hori Masaru Takagi Gerard Bengua Ken-ichi Kamo Kaori Sato Hiromitsu Takeda Masato Hareyama Koh-ichi Sakata Jun Takada

This study sought to demonstrate the feasibility of estimating the source strength during implantation in brachytherapy. The requirement for measuring the strengths of the linked sources was investigated. The utilized sources were (125)I with air kerma strengths of 8.38-8.63 U (μGy m(2) h(-1)). Measurements were performed with a plastic scintillator (80 mm × 50 mm × 20 mm in thickness). For a s...

2016

The estimation of the mean glandular dose to the breast (MGD) for x-ray based imaging modalities forms an essential part of quality control and is needed for risk estimation and for system design and optimisation. This review considers the development of methods for estimating the MGD for mammography, digital breast tomosynthesis (DBT) and dedicated breast CT (DBCT). Almost all of the methodolo...

2008
Mércia L Oliveira Marcus Aurélio P dos Santos Clayton A Benevides Luiz Freire

Radiation protection monitoring instruments should be calibrated by accredited calibration laboratories. To offer calibration services, a laboratory must accomplish all requirements established by the national regulatory agency. The Calibration Service of the Centro Regional de Ciências Nucleares (CRCN-NE), Comissão Nacional de Energia Nuclear, Recife, Brazil, is trying to achieve this accredit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید