نتایج جستجو برای: ti contact

تعداد نتایج: 196715  

2017
P. Lettenmeier R. Wang R. Abouatallah B. Saruhan O. Freitag P. Gazdzicki T. Morawietz R. Hiesgen A. S. Gago K. A. Friedrich

Cost reduction and high efficiency are the mayor challenges for sustainable H2 production via proton exchange membrane (PEM) electrolysis. Titanium-based components such as bipolar plates (BPP) have the largest contribution to the capital cost. This work proposes the use of stainless steel BPPs coated with Nb and Ti by magnetron sputtering physical vapor deposition (PVD) and vacuum plasma spray...

Journal: :Metallomics : integrated biometal science 2014
J Soto-Alvaredo E Blanco J Bettmer D Hevia R M Sainz C López Cháves C Sánchez J Llopis A Sanz-Medel M Montes-Bayón

Metallic implants placed in humans exhibit wear and corrosion that result in the liberation of metal-containing by-products. In the case of titanium (Ti) containing implants, the metal containing debris may exist in a number of states, including metallic particles produced by mechanical wear and the products of metal corrosion in biological environments, such as the joints and surrounding fluid...

Journal: :Brazilian dental journal 2005
Cristina de Almeida Costa Lídia Agata Sena Marcelo Pinto Carlos Alberto Muller José Henrique Lima Cavalcanti Glória de Almeida Soares

This study compared in vivo the performances of commercially pure titanium (cp Ti) screw dental implants either uncoated or coated with synthetic hydroxyapatite (HA) by electrophoresis. The HA coating was characterized by scanning electron microscopy, energy dispersive spectroscopy (EDS) and Fourier-transform infrared (FT-IR) spectroscopy. Well-adhered carbonated-hydroxyapatite layers (4- to-8-...

2012
Dai Yamamoto Ikki Kawai Kensuke Kuroda Ryoichi Ichino Masazumi Okido Azusa Seki

Various techniques for forming TiO(2) coatings on Ti have been investigated for the improvement of the osteoconductivity of Ti implants. However, it is not clear how the oxidizing process affects this osteoconductivity. In this study, TiO(2) coatings were prepared using the following three processes: anodizing in 0.1 M H(3)PO(4) or 0.1 M NaOH aqueous solution; thermal oxidation at 673 K for 2 h...

1999
E. Liu X. Shi L. K. Cheah Y. H. Hu H. S. Tan J. R. Shi B. K. Tay

Silicon and GaAs based devices are limited in their high-temperature applications as these materials lack high sensitivity to the temperature range above 200°C due to their small band gaps. Therefore, exploration of new materials with a high-temperature performance is necessary. Diamond-like carbon as a semiconducting material may be one of the promising candidates due to its many properties cl...

Journal: :Journal of biomedical materials research. Part A 2010
Cristina Treves Maria Martinesi Maria Stio Alejandro Gutiérrez José Antonio Jiménez María Francisca López

The present work is aimed to evaluate the effects of a surface modification process on the biocompatibility of three vanadium-free titanium alloys with biomedical applications interest. Chemical composition of alloys investigated, in weight %, were Ti-7Nb-6Al, Ti-13Nb-13Zr, and Ti-15Zr-4Nb. An easy and economic method intended to improve the biocompatibiblity of these materials consists in a si...

Journal: :Istraživanja i projektovanja za privredu 2022

This article presents the results of studying temperature distribution in process thermo-frictional cutting titanium alloy Ti-5553. The was simulated using Machining module DEFORM 3D software package based on finite element method. It found that when off Ti-5553, depending geometry circular saw, "disk-workpiece" contact zone reached T = 800 ÷ 1130 °C, and its propagation into depth workpiece 0....

2014
J. I. Simon J. E. P. Matzel S. B. Simon P. K. Weber L. Grossman D. K. Ross I. D. Hutcheon

Introduction: Wark-Lovering (WL) rims [1] surrounding many refractory inclusions represent marker events in the early evolution of the Solar System in which many inclusions were exposed to changes in pressure [2], temperature [3], and isotopic reservoirs [4-7]. The effects of these events can be complex, not only producing mineralogical variability of WL rims [2], but also leading to mineralogi...

The present study aimed to assess the effect of replacing copper as a multi-functional ingredient in the brake pad material with potassium titanate platelet (PTP) and a particular type of ceramic fiber (CF) copper-free composite. Chase dynamometer tests were conducted to compare a brake padchr('39')s tribological behavior when PTP and CF are added to the composition with that of the copper-bear...

2017
Ryo Yagi Chihiro Mochizuki Mitsunobu Sato Takeshi Toyama Masatsugu Hirota Tohru Hayakawa Chikahiro Ohkubo

We performed thin carbonate-containing apatite (CA) coating on titanium (Ti) by an aqueous spray coating (ASC) method that consisted of a Ca-CO₃-PO₄ complex. Two different CA coatings were produced by two different spray amounts and were heat-treated after spraying. We evaluated three-dimensional structures, adhesiveness to Ti, and durability of the CA film. In addition, we performed immersion ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید