نتایج جستجو برای: tcd

تعداد نتایج: 1241  

Journal: :General Relativity and Gravitation 2022

We give an example of a spacetime with continuous metric which is globally hyperbolic and exhibits causal bubbling. The moreover splits orthogonally into timelike spacelike part. discuss our in the context energy conditions recently introduced synthetic curvature-dimension (TCD) condition. In particular we observe that TCD-condition does not, by itself, prevent

2013
M. HELMI. AFIFI MOUSTAFA M. MOUSTAFA

The aim of the study was to determine the specificity and sensitivity of Transcranial Doppler Sonography (TCD) as a confirmatory test for diagnosis of brain death and to assess the possibility of adding this test to the protocol for diagnosis of brain death in ICU. TCD examination was done in 20 patients (group I) with brain death confirmed either by clinical assessment and EEG (17 patients) or...

2010
Marcel J. H. Aries Jan W. Elting Jacques De Keyser Berry P. H. Kremer Patrick C. A. J. Vroomen

Background and Purpose—Cerebral autoregulation may become impaired after stroke. To provide a review of the nature and extent of any autoregulation impairment after stroke and its course over time, a technique allowing repeated bedside measurements with good temporal resolution is required. Transcranial Doppler (TCD) in combination with continuous blood pressure measurements allows noninvasive ...

Journal: :Stroke 2002
Dirk W Droste Stefan Lakemeier Thomas Wichter Jörg Stypmann Ralf Dittrich Martin Ritter Martin Moeller Michael Freund E Bernd Ringelstein

BACKGROUND AND PURPOSE A cardiac right-to-left shunt (RLS) can be identified by transesophageal echocardiography and transcranial Doppler ultrasound (TCD) with contrast agents and a Valsalva maneuver (VM) as a provocation procedure. This article applies the modalities of these tests detailed in previous studies to a large patient cohort and compares 2 contrast agents (saline and Echovist-300). ...

Journal: :Stroke 2010
Marta Rubiera Luis Cava Georgios Tsivgoulis Damon E Patterson Limin Zhao Yi Zhang Aaron M Anderson Alice Robinson Mark R Harrigan Edward Underwood Joseph Horton Andrei V Alexandrov

BACKGROUND AND PURPOSE Intra-arterial (IA) rescue procedures are increasingly used to treat acute ischemic stroke. We implemented continuous transcranial Doppler (TCD) monitoring during these procedures to detect any potentially harmful flow changes. Here, we report diagnostic criteria and yield of TCD monitoring. METHODS We studied consecutive acute stroke patients who underwent IA reperfusi...

2011
Vibol Chhor Yannick Le Manach Fréderic Clarençon Aurélien Nouet Jean-Louis Daban Lamine Abdennour Louis Puybasset Thomas Lescot

INTRODUCTION Cerebral vasospasm is a well-documented complication of aneurismal subarachnoid hemorrhage but has not been extensively studied in brain arteriovenous malformations (BAVMs). Here, our purpose was to identify risk factors for cerebral vasospasm after BAVM rupture in patients requiring intensive care unit (ICU) admission. METHODS Patients admitted to our ICU from January 2003 to Ma...

Journal: :Blood 1998
B R Blazar P A Taylor R McElmurry L Tian A Panoskaltsis-Mortari S Lam C Lees T Waldschmidt D A Vallera

Although in utero transplantation (IUT) has been shown to be effective in treating human severe combined immune deficiency (SCID), the relative merit of IUT as compared with postnatal bone marrow transplantation (BMT) for SCID is unknown. Therefore, comparative studies were undertaken in mice to determine the engraftment outcome in these two settings. Because T-cell depletion (TCD) reduces graf...

Journal: :Seizure 2014
Sybille Merceron Thomas Geeraerts Claire Montlahuc Jean-Pierre Bedos Matthieu Resche-Rigon Stéphane Legriel

PURPOSE We assessed the accuracy of transcranial Doppler (TCD) in helping to diagnose nonconvulsive status epilepticus (NCSE) in comatose patients admitted to the intensive care unit (ICU) for acute neurological disorders at high risk for NCSE. METHODS A 2-year prospective observational study in 38 consecutive patients requiring continuous electroencephalography (EEG) monitoring and intracran...

Journal: :Stroke 1994
M Jauss M Kaps M Keberle W Haberbosch W Dorndorf

BACKGROUND Patent foramen ovale as a possible stroke risk factor can be diagnosed with transcranial Doppler sonography (TCD) by detecting intravenous contrast medium crossing from the right to the left atrium. The present study evaluates the reliability of this method. SUMMARY OF REPORT We performed TCD and transesophageal echocardiography simultaneously in 50 patients using galactose microbu...

Journal: :J. Parallel Distrib. Comput. 2000
Songluan Cang Jie Wu

In this paper we propose a new minimum total communication distance (TCD) algorithm and anoptimal TCD algorithm for broadcast in a 3-dimensional mesh (3-D mesh). The former generatesa minimum TCD from a given source node, and the latter guarantees a minimum TCD among allthe possible source nodes. These algorithms are based on a divide-and-conquer approach where a3-D mesh is ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید