نتایج جستجو برای: microelectrode

تعداد نتایج: 3833  

Journal: :Journal of neurophysiology 2008
David D Cox Alexander M Papanastassiou Daniel Oreper Benjamin B Andken James J Dicarlo

Much of our knowledge of brain function has been gleaned from studies using microelectrodes to characterize the response properties of individual neurons in vivo. However, because it is difficult to accurately determine the location of a microelectrode tip within the brain, it is impossible to systematically map the fine three-dimensional spatial organization of many brain areas, especially in ...

2008
YAO-MING YU

This work presents a simple, flexible and economical microwire array electrode for extracellular cortical recordings. The proposed procedure is relatively simple, even for a novice worker to implement in-house. These main steps include design and sculpturing PCB, straightening microwires, connecting PCB pattern, arraying and soldering microwires and packaging the microelectrode. A practiced res...

Journal: :American journal of physiology. Heart and circulatory physiology 2001
R D Braun J L Lanzen S A Snyder M W Dewhirst

In this study we compare oxygen tension (PO2) histograms measured with O2 microelectrodes and a new optical PO2 measurement device, the OxyLite, in normal tissues (mouse spleen and thymus) and in tumors (R3230Ac in rats) (n = 5-6). The transient response to glucose infusion or 100% O2 breathing (hyperoxia) was also measured in tumors. PO2 histograms of spleen and thymus with the two devices wer...

2006
Lingyan Wang Nancy N. Kariuki Mark Schadt Derrick Mott Jin Luo Chuan-Jian Zhong Xiajing Shi Chen Zhang Weibing Hao Susan Lu Nam Kim Jian-Q. Wang

This paper describes the results of a study of a few design parameters influencing the performance of sensor arrays constructed from nanostructured thin films and interdigitated microelectrodes (IMEs). The nanostructured thin films on the IME devices were prepared from nonanedithiol (NDT) and mercaptoundecanoic acid (MUA) linked assemblies of 2-nm sized gold nanoparticles. The sensor array data...

2001
Yi Wang Samuel P. Kounaves

A nitrilase-modiiied glassy carbon microelectrode for the detection of benzonitrile in water was developed and analytically characterized. The detection scheme uses Rhodococcus sp. nitrilase to catalyze the hydrolysis of benzonitrile derivatives directly into carboxylic acid and ammonia. The glassy carbon microelectrode surface modillcation was accomplished by attaching a hydrophilic tether to ...

2015
Muhamad Ramdzan Buyong Farhad Larki Mohd Syafiq Faiz Azrul Azlan Hamzah Jumrail Yunas Burhanuddin Yeop Majlis

In this work, the dielectrophoretic force (F(DEP)) response of Aluminium Microelectrode Arrays with tapered profile is investigated through experimental measurements and numerical simulations. A standard CMOS processing technique with a step for the formation of a tapered profile resist is implemented in the fabrication of Tapered Aluminium Microelectrode Arrays (TAMA). The F(DEP) is investigat...

2015
Sangmin Lee Jae Hyun Ahn Jong-Mo Seo Hum Chung Dong-Il Cho

In order to provide high-quality visual information to patients who have implanted retinal prosthetic devices, the number of microelectrodes should be large. As the number of microelectrodes is increased, the dimensions of each microelectrode must be decreased, which in turn results in an increased microelectrode interface impedance and decreased injection current dynamic range. In order to imp...

Journal: :Vision Research 2011
Kai Wang Xiao-Qian Li Xiao-Xin Li Wei-Hua Pei Hong-Da Chen Jian-Qiang Dong

In addition to epiretinal and subretinal areas, the optic nerve (ON) is also a candidate location for implanting visual prosthesis to restore vision of patients with retinitis pigmentosa (RP). Since the ON receives all the signals from the retina, stimulating the ON may potentially evoke phosphenes over a wider range of visual field. In this study, we designed a 9-channel microelectrode array a...

2016
Feifei Tong Yan Lian Junliang Han

Biological information is obtained from the interaction between the series detection electrode and the organism or the physical field of biological cultures in the non-mass responsive piezoelectric biosensor. Therefore, electric parameter of the electrode will affect the biosensor signal. The electric field distribution of the microelectrode used in this study was simulated using the COMSOL Mul...

Journal: :Neurosurgical focus 2006
Paul A House Joel D MacDonald Patrick A Tresco Richard A Normann

OBJECT Researchers at The Center for Neural Interfaces at the University of Utah have designed and produced a silicon-based high-density microelectrode array that has been used successfully in mammalian models. The authors investigate the ability to transfer array insertion techniques to humans and examine the acute response of human cortical tissue to array implantation. METHODS Six patients...

نمودار تعداد نتایج جستجو در هر سال