نتایج جستجو برای: finite element gafchromic film
تعداد نتایج: 481855 فیلتر نتایج به سال:
A stiff thin film bonded to a pre-strained, compliant substrate wrinkles into a sinusoidal form upon release of the pre-strain. Many analytical models developed for the critical pre-strain for wrinkling assume that the substrate is semi-infinite. This critical pre-strain is actually much smaller than that for a substrate with finite thickness (Ma Y et al. 2016 Adv. Funct. Mater. (doi:10.1002/ad...
Measurement of skin dose variations produced by a silicon-based protective dressing in radiotherapy.
Variations in skin dose caused by a silicon-based burn dressing used in radiotherapy during treatment have been investigated. Measurement of these variations in skin dose has been achieved using thermoluminescent dosimeters (TLDs) and Gafchromic film. For a 6 MV x-ray beam results have shown that an approximately 0.4 mm thick silicon mesh dressing increases the average surface dose by approxima...
PURPOSE Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of information about interaction cross-sections, which are determined not only by electron density but also by atomic number. TG-186 recommendations with using of MBDCA (model-based dose calculation algorithm), accurate tissues segmentation, and the structure's elemental composition continue to create difficulti...
Assessment of skin dose delivered to patients from radiotherapy x-ray beams should be performed both inside and outside the prescribed treatment fields. A multilayer Gafchromic film detector which has high sensitivity for detection of radiation can be used to measure skin dose in a two-dimensional map over the skin surface if required. This is an advantage over other detectors, which only provi...
PURPOSE To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. ...
Normal and cancerous tissue have changing values of Electrical Impedance Spectroscopy (EIS). In which with comparing their impedance spectrum with bio-impedance measuring system, they can be used for cancerous tissue diagnosis. Probe is the main part in electrical impedance measurement system. In this paper by employing finite element method EIS factor of mucous tissue derived in 5 different pr...
We present a mixed finite element method for the thin film epitaxy problem. Comparing to the primal formulation which requires C2 elements in the discretization, the mixed formulation only needs to use C1 elements, by introducing proper dual variables. The dual variable in our method is defined naturally from the nonlinear term in the equation, and its accurate approximation will be essential f...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید