Voltammetric and Potentiometric Behavior of 2-Pyridinethiol, 2-Mercaptoethanol and Sulfide at Iron(II) Phtalocyanine Modified Carbon-Paste Electrode

نویسندگان

  • Iraj Mohammadpoor Baltork Chemistry Department, University of Isfahan, Isfahan, Zip code 81744, I.R. IRAN
  • Said Shahrokhian Chemistry Department, University of Isfahan, Isfahan, Zip code 81744, I.R. IRAN
  • Sharam Tangestaninejad Chemistry Department, University of Isfahan, Isfahan, Zip code 81744, I.R. IRAN
چکیده مقاله:

A carbon-past electrode modified with iron(II) phathalocyanine (FePc) was used as a sensitive potentiometric sensor for determination of 2-pyridinethiol (2PT). 2-mercaptoethanol (2ME) and sulfide ion in aqueous solutions. The modified electrode acts as an electrocatalyst for oxidation of these compounds, and lowers the overpotential for oxidation reactions by more than 400 mV, compared to the unmodified electrode. The process was dependent on the pH of the supporting electrolyte. The fast rate of electron transfer results in a near-Nernstian behavior of the modified electrode, and makes it a suitable potentiometric sensor for measurement of these compounds. Calibration studies were performed using potentiometry in oxygen or air saturated stirred solutions; linear responses were obtained over the range of about 1´10-6 to 5´10-3 M (correlation coefficients, r, of ~0.999, n=8). The modified electrode exhibited a fast response time (< 20 s), good stability, and has an extended lifetime; the standard deviation of slopes, during a period of two months, was 1.7-2.4% (n=10). Appropriate electrochemical and analytical data are presented.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

voltammetric and potentiometric behavior of 2-pyridinethiol, 2-mercaptoethanol and sulfide at iron(ii) phtalocyanine modified carbon-paste electrode

a carbon-past electrode modified with iron(ii) phathalocyanine (fepc) was used as a sensitive potentiometric sensor for determination of 2-pyridinethiol (2pt). 2-mercaptoethanol (2me) and sulfide ion in aqueous solutions. the modified electrode acts as an electrocatalyst for oxidation of these compounds, and lowers the overpotential for oxidation reactions by more than 400 mv, compared to the u...

متن کامل

Voltammetric determination of cysteine at a carbon paste electrode modified with Cu(II)-salen complex

The electrochemical behavior of a modified carbon paste electrode (MCPE) with N,N′ethylenbis(salicylideneiminato)copper(II) complex ([Cu(II)-Salen]) was investigated as a newsensor for cystein. The Britton-Robinson buffer with pH 5, 10% modifier in electrode, potentialscanning rate of 20 mVs-1 and puls height of 50 mV were used as the optimum condition for thedetermination of cysteine using car...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Electrochemical Behavior and Voltammetric Determination of a Manganese(II) Complex at a Carbon Paste Electrode

Investigation of the electrochemical behavior using cyclic voltammetry and detection of [Mn(2+)(thiophenyl-2-carboxylic acid)2 (triethanolamine)] with adsorptive stripping differential pulse voltammetry. The electrochemical behavior of a manganese(II) complex [Mn(2+)(thiophenyl-2-carboxylic acid)2(triethanolamine)] (A) was investigated using cyclic and differential pulse voltammetry in an aceta...

متن کامل

Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods

A chemically modified carbon paste electrode with multiwall carbon nanotube (MWCNT) was prepared and used as a sensor for Cu2+  ion. The unique chemical and physical properties of CNT have paved the way  to  new  and  improved  sensing  devices.  A  central  composite chemometrics  design  was  applied  for  multivariate  optimization  of the  effects  of  three  significant  parameters  (...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 20  شماره 1

صفحات  26- 36

تاریخ انتشار 2001-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023