Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid
نویسندگان
چکیده مقاله:
Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determination of ultra-trace amounts of cadmium (II),. Materials and Methods: In this study, a new membrane ion selective electrode was constructed with a composition entailed of 10% nefazodone, 2% [BMIM]PF6, 30% PVC and 58% dioctyl phthalate (DOP).The created potential discrepancy between the membrane and reference electrodes was used as a signal which demonstrates a direct relationship with the logarithmic concentration of cadmium (II) for its determination. Results: The constructed sensor showed an appropriate Nernstian slope (30.5 mV. Decade-1) in a wide concentration range (1×10-9 - 8×10-2 M) with the detection limit of 6×10-9 M. The electrode potential was pH-independent in the range of 3.5-8.0. The response time and lifetime of the electrode obtained 5 s and 15 weeks, respectively. Conclusion: The constructed sensor independent of sample preparation was employed successively for the measurement of low concentrations of cadmium (II) in the environmental samples .Moreover, the obtained findings were in a good agreement with the results of flame atomic absorption spectroscopy. Therefore, the designed electrode established pinpoint accuracy and it can be used for the determination of cadmium (II) in aqueous samples.
منابع مشابه
Ionic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction and High-performance Liquid Chromatography for the Trace Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples
A green and efficient ionic liquid-based ultrasound-assisted in-situ solvent formationmicroextraction (IL-UA-ISFME) in combination with high-performance liquid chromatographyultravioletdetection (HPLC-UV) has been successfully developed for the trace determination offive selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In thismethod, a hydrophobic ionic liquid (1...
متن کاملLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملInfluence of counterions on micellization of tetramethylammonium perfluorononanoic carboxylate in 1-butyl-3-methylimidazolium ionic liquid.
The influence of counterions on micellization of perfluorononanoic carboxylate ammonium salts in water and 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim]BF(4)) solutions was investigated by surface tension and (19)F NMR measurements and freeze-fracture transmission electron microscopy (FF-TEM) observations. Changes in the counterions of the fluorocarbon surfactants have different effects...
متن کاملApplication of Cold-Induced Aggregation Microextraction Based on Ionic Liquid for Determination of Trace Amount of Cadmium and Lead in Powder Milk Samples
Background: cold-induced aggregation micro extraction based (CIAME) based on ionic liquid was used as a rapid and simple method for determination trace amounts of cadmium and lead in milk powder by analysis with flame atomic absorption spectrometry (FAAS). Methods: Sample solution containing of Cd2+ and Pb2+ in dynamic range, phosphate buffer (pH = 9, 3 ml), diethyl dithiocarbamate (complexin...
متن کاملInfluence of Ionic Liquid 1- butyl-3-methylimidazolium Chloride on the Soil Micro-Ecological System
In order to evaluate the influence of ionic liquid 1butyl-3-methylimidazolium chloride ([Bmim]Cl) on the soil micro-ecological system, the toxicity of [Bmim]Cl to soil microorganisms and its impact on soil physico-chemical properties were investigated. Three soil samples, which were taken from the rape land, nursery land and the broad bean land respectively, were used for this study. The toxici...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 13 شماره 3
صفحات 455- 468
تاریخ انتشار 2020-11
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023