Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods, including Compton spectrometry, are usually used to determine the X-ray spectrum in diagnostic energy range. The x-ray spectrum could be unfolded using radiation absorbing materials, proper detectors. Materials and Methods: The Compton scattering procedure was simulated using MCNP5 Monte Carlo code. The pulse height distributions (PHD) recorded by HPGe detector were simulated for different primary beam spectra. Then the primary spectrum was reconstructed using Tikhonov unfolding technique. Results: The results of this study indicate that this study, the x-ray spectra for 40, 50, 80, and 100kVp were unfolded with good accuracy. Conclusion: Tikhonov method may be effectively used in unfolding x ray spectra using Compton spectroscopy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

Quantifying the effect of anode surface roughness on diagnostic x-ray spectra using Monte Carlo simulation.

PURPOSE The accurate prediction of x-ray spectra under typical conditions encountered in clinical x-ray examination procedures and the assessment of factors influencing them has been a longstanding goal of the diagnostic radiology and medical physics communities. In this work, the influence of anode surface roughness on diagnostic x-ray spectra is evaluated using MCNP4C-based Monte Carlo simula...

متن کامل

[Measurement of response function of CdTe detector using diagnostic X-ray equipment and evaluation of Monte Carlo simulation code].

An X-ray spectrum measured with CdTe detector has to be corrected with response function, because the spectrum is composed of full energy peaks (FEP) and escape peaks (EP). Recently, various simulation codes were developed, and using them the response functions can be calculated easily. The aim of this study is to propose a new method for measuring the response function and to compare it with t...

متن کامل

monte carlo simulation of a 6 mv x-ray beam for open and wedge radiation fields, using gate code

the aim of this study is to provide a control software system, based on monte carlo simulation, and calculations of dosimetric parameters of standard and wedge radiation fi elds, using a monte carlo method. gate version 6.1 (opengate collaboration), was used to simulate a compact 6 mv linear accelerator system. in order to accelerate the calculations, the phase-space technique and cluster compu...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  48- 48

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023