Ultrasound Measurements of the ECRB Tendon Shows Remarkable Variations in Patients with Lateral Epicondylitis

نویسندگان

  • Annechien Beumer Department of Orthopaedic Surgery, Upper limb unit, Amphia Hospital, Breda, the Netherlands--- Coronel Institute of Occupational health, Amsterdam University Medical Centers, the Netherlands
  • Bertram The Department of Orthopaedic Surgery, Upper limb unit, Amphia Hospital, Breda, the Netherlands
  • Denise Eygendaal Department of Orthopaedic Surgery, Amsterdam University Medical Centers, the Netherlands
  • Koen L.M. Koenraadt Foundation for Orthopaedic Research, Care and Education, Amphia Hospital, Breda, the Netherlands
  • Renée Keijsers Department of Orthopaedic Surgery, Upper limb unit, Amphia Hospital, Breda, the Netherlands
چکیده مقاله:

Background: Lateral epicondylitis (LE) most commonly affects the Extensor Carpi Radialis Brevis (ECRB) tendon andpatients are generally treated with injection therapy. For optimal positioning of the injection, as well as an estimation ofthe surface area and content of the ECRB tendon to determine the volume of the injectable needed, it is important toknow the exact location of the ECRB in relation to the skin as well as the variation in tendon length and location. Theaim of this study was to determine the variation in location and size of the ECRB tendon in patients with LE.Methods: An observational sonographic evaluation of the ECRB tendon was performed in 40 patients with LE. Thelength of the ECRB tendon, distance from the cutis to the center of the ECRB tendon, the length of the osteotendinousjunction at the epicondyle and the distance from cutis to middle of the osteotendinous junction were measured.Results: The average tendon length was 1.68cm (range 1.27-1.98; SD 0.177). Compared to women, the ECRB tendonof men was on average 0.12cm longer. Overall, the average distance from cutis to the center of the ECRB was 0.75cm(range 0.50-1.46cm; SD 0.210), the average length of the junction was 0.55cm (range 0.35-0.87; SD 0.130), and thedistance from cutis to middle of the osteotendinous junction was 0.73cm (range 0.40-1.25cm; SD 0.210).Conclusion: The size and depth of the ECRB tendon in patients with LE is largely variable. While there are no studiesyet suggesting sono-guided injection to be superior to that of blind injection, the anatomic variability of this studysuggests that the accuracy of injection therapy for LE might be compromised when based solely on bony landmarksand therefore not fully reliable. As a result, there is value in further studies exploring the accuracy of the ultrasoundguided injection techniques.Level of evidence: IV

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR Imaging of Patients with Lateral Epicondylitis of the Elbow: Is the Common Extensor Tendon an Isolated Lesion?

OBJECTIVE To investigate whether an injury of the common extensor tendon (CET) is associated with other abnormalities in the elbow joint and find the potential relationships between these imaging features by using a high-resolution magnetic resonance imaging (MRI). METHODS Twenty-three patients were examined with 3.0 T MR. Two reviewers were recruited for MR images evaluation. Image features ...

متن کامل

Radial shock wave therapy in patients with lateral epicondylitis.

INTRODUCTION Lateral epicondylitis, or "tennis elbow", is a relatively common disorder. Various therapeutic modalities have been tried in an attempt to manage the disorder but neither the conservative methods nor the surgical options have proved to be beneficial so far. During the past decade in the USA and European countries and the past several years in Bulgaria, the shock wave therapy (focus...

متن کامل

Magnetic Resonance Imaging of Patients With Chronic Lateral Epicondylitis

The aim of the study is to determine the inter-reliability and intra-observer reliability of magnetic resonance imaging (MRI) for lateral epicondylitis and investigate whether there is a potential relationship between MRI abnormalities of the common extensor tendon (CET) and its clinical symptom. The study group comprised 96 consecutive patients (46 men and 50 women) with a clinical diagnosis o...

متن کامل

ultrasound measurements of the lateral abdominal muscle thicknesses in girls with adolescent idiopathic scoliosis

conclusions the eo muscle was thinner and had higher activity during adim in the ais group. analysis of our data showed that in the ais group the higher the lumbar spinal curve to the right, the thicker the right tra compared to the left tra. results there was no side to side asymmetry in muscle thickness at rest and also during adim in two groups. thickness of right eo [0.39 (0.09) in the ais ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 2

صفحات  168- 172

تاریخ انتشار 2020-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023