Tomographic Reconstruction of the Ionospheric Electron Density in term of Wavelets
نویسندگان
چکیده مقاله:
Ionospheric tomography is a method to investigate the ionospheric electron density in two or three dimensions. In this study, the function-based tomographic technique has been used for regional reconstruction of a 3D tomographic model of the ionospheric electron density using the GPS measurements of the Iranian Permanent GPS Network. Two-dimensional Haar wavelets and empirical orthogonal functions are used as base functions to model the horizontal and the vertical structure of the electron density, respectively. Sparseness of data and data gaps make ionospheric tomography an ill-posed inverse problem. The truncated singular value decomposition (TSVD) method is used to come up with solution. The data analysis results show that the latitudinal sections of the electron density in ionosphere obtained from the tomographic technique supports the expected time and height variations in the electron density. Moreover, these findings show that the height of maximum electron density is changed during the day. This confirms the efficiency of the developed multilayer model in comparison to the traditional single-layer ones. The relative error between the reconstructed electron density and the electron density obtained from ionosonde data varies between 5 to 35 percent. The difference between the reconstructed electron density (as well as the corresponding estimations of the IRI-2001 model) and the direct estimates of this quantity increases when the electron density reaches to its maximum value. Assuming that the ionosonde station in Tehran produces reliable results, this proves that the reconstructed image as well as the IRI-2001 model does not efficiently constraint the electron density during this period of time.
منابع مشابه
Tomographic reconstruction of the ionospheric electron density as a function of space and time
Electron density distribution is the major determining parameter of the ionosphere. Computerized Ionospheric Tomography (CIT) is a method to reconstruct ionospheric electron density image by computing Total Electron Content (TEC) values from the recorded Global Positioning Satellite System (GPS) signals. Due to the multi-scale variability of the ionosphere and inherent biases and errors in the ...
متن کاملApplication of hybrid regularization method for tomographic reconstruction of midlatitude ionospheric electron density
Reconstructing ionospheric electron density (IED) is an ill-posed inverse problem, with classical Tikhonov regularization tending to smooth IED structures. By contrast, total variation (TV) regularization effectively resists noise and preserves discontinuities of the IED. In this paper, we regularize the inverse problem by incorporating both Tikhonov and TV regularization. A specific formulatio...
متن کاملthe effect of traffic density on the accident externality from driving the case study of tehran
در این پژوهش به بررسی اثر افزایش ترافیک بر روی تعداد تصادفات پرداخته شده است. به این منظور 30 تقاطع در شهر تهران بطور تصادفی انتخاب گردید و تعداد تصادفات ماهیانه در این تقاطعات در طول سالهای 89-90 از سازمان کنترل ترافیک شهر تهران استخراج گردید و با استفاده از مدل داده های تابلویی و نرم افزار eviews مدل خطی و درجه دوم تخمین زده شد و در نهایت این نتیجه حاصل شد که تقاطعات پر ترافیک تر تعداد تصادفا...
15 صفحه اولTomographic reconstruction of ionospheric electron density during the storm of 5-6 August 2011 using multi-source data
The insufficiency of data is the essential reason for ill-posed problem existed in computerized ionospheric tomography (CIT) technique. Therefore, the method of integrating multi-source data is proposed. Currently, the multiple satellite navigation systems and various ionospheric observing instruments provide abundant data which can be employed to reconstruct ionospheric electron density (IED)....
متن کاملTomographic reconstruction using nonseparable wavelets
In this paper, the use of nonseparable wavelets for tomographic reconstruction is investigated. Local tomography is also presented. The algorithm computes both the quincunx approximation and detail coefficients of a function from its projections. Simulation results showed that nonseparable wavelets provide a reconstruction improvement versus separable wavelets.
متن کاملthe effects of keyword and context methods on pronunciation and receptive/ productive vocabulary of low-intermediate iranian efl learners: short-term and long-term memory in focus
از گذشته تا کنون، تحقیقات بسیاری صورت گرفته است که همگی به گونه ای بر مثمر ثمر بودن استفاده از استراتژی های یادگیری لغت در یک زبان بیگانه اذعان داشته اند. این تحقیق به بررسی تاثیر دو روش مختلف آموزش واژگان انگلیسی (کلیدی و بافتی) بر تلفظ و دانش لغوی فراگیران ایرانی زیر متوسط زبان انگلیسی و بر ماندگاری آن در حافظه می پردازد. به این منظور، تعداد شصت نفر از زبان آموزان ایرانی هشت تا چهارده ساله با...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 7 شماره 1
صفحات 19- 29
تاریخ انتشار 2631-04-21
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023