The determination of Cu2+, Fe3+, Zn2+ and Pb2+ in real samples by flame atomic absorption spectrometry after their separation- preconcentration on 2-(2-nitrophenylazo)- naphthalen-1-ol loaded on activated carbon
نویسندگان
چکیده مقاله:
A sensitive and simple method for simultaneous preconcentration of trace heavy metal ions in some cerealand vegetable samples has been reported. The method is based on the adsorption of Cu2+, Fe3+, Zn2+ and Pb2+on 2-(2-nitro-phenylazo)-naphthalen-1-ol (NPN) loaded on activated carbon (AC). The adsorbed metals onactivated carbon were eluted using 3 ml 4 mol L−1 nitric acid. The influences of the analytical parametersincluding pH, flow rate of sample and eluent, type and concentration of eluent, amount of adsorbent andsample volume were investigated. The effects of matrix ions on the recoveries of analyte ions were alsoinvestigated. The recoveries of analytes were generally higher than 95%. The detection limits for Cu2+, Fe3+,Zn2+ and Pb2+ were 0.17 μg L-1 , 0.16 μg L-1 ,0.11 μg L-1 and 0.12 μg L-1 respectively.
منابع مشابه
the determination of cu2+, fe3+, zn2+ and pb2+ in real samples by flame atomic absorption spectrometry after their separation- preconcentration on 2-(2-nitrophenylazo)- naphthalen-1-ol loaded on activated carbon
a sensitive and simple method for simultaneous preconcentration of trace heavy metal ions in some cerealand vegetable samples has been reported. the method is based on the adsorption of cu2+, fe3+, zn2+ and pb2+on 2-(2-nitro-phenylazo)-naphthalen-1-ol (npn) loaded on activated carbon (ac). the adsorbed metals onactivated carbon were eluted using 3 ml 4 mol l−1 nitric acid. the influences of the...
متن کاملDetermination of beryllium in solid samples by flame atomic absorption spectrometry after preconcentration on activated carbon.
It is generally supposed that the preconcentration procedure is used for the determination of metal concentrations under the sensitivity of the measurement method. This study showed that preconcentration is also need for the beryllium (Be) concentration over the sensitivity of atomic absorption spectrometry. For this purpose, a simple and selective method for the determination of Be in solid sa...
متن کاملDetermination of Rhodium(III) Ions by Flame Atomic Absorption Spectrometry after Preconcentration with Modified Magnetic Activated Carbon
A new method for analysis of trace amount of Rh(III) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (MAC/TPPZ) as the magnetic sorbent has been proposed. The proposed adsorbent was found to be advantageous over conventional solid phase extraction (SPE) in terms of operational simplicity and low time-consuming. The experimental parameters affecting the extractio...
متن کاملPreconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry
A simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (IL-DLLME)method, followed by flame atomic absorption spectrometry (FAAS) was developed for the preconcentrationand determination of palladium in water samples. In this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...
متن کاملdetermination of rhodium(iii) ions by flame atomic absorption spectrometry after preconcentration with modified magnetic activated carbon
a new method for analysis of trace amount of rh(iii) ions by magnetic activated carbon modified with 2,3,5,6-tetra(2-pyridyl)pyrazine (mac/tppz) as the magnetic sorbent has been proposed. the proposed adsorbent was found to be advantageous over conventional solid phase extraction (spe) in terms of operational simplicity and low time-consuming. the experimental parameters affecting the extractio...
متن کاملDetermination of Cadmium by Flame-Atomic Absorption Spectrometry After Preconcentration on Silica Gel Modified with Cupferron
Este trabalho descreve um método para a pré-concentração de cádmio com sílica gel modificada com cupferron e sua determinação por espectrometria de absorção atômica com chama. O efeito do pH, a quantidade do material adsorvente, a concentração de eluente, volume da amostra e quantidade do analito adsorvido foram otimizados. O efeito de interferentes foi avaliado para diversos íons mostrando que...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 2
صفحات 55- 63
تاریخ انتشار 2012-06-20
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023