SMART ROOM CARBON MONOXIDE MONITORING AND CONTROL SYSTEM

نویسندگان

  • Bello Nuhu Department of Computer Engineering, Federal University of Technology, Minna, Nigeria
  • Chinedu Onyema Department of Computer Engineering, Federal University of Technology, Minna
  • Dauda Idris Department of Computer Engineering, Federal University of Technology, Minna
  • Olayemi Olaniyi Department of Computer Engineering, Federal University of Technology, Minna, Niger State, Nigeria
چکیده مقاله:

Carbon Monoxide (CO) is the most abundant air pollutant gas and accumulates rapidly to dangerous concentrations even in areas that seem to be well ventilated. Carbon monoxide detectors/alarm systems exist but people who are old, hearing impaired, partially sighted or heavy sleepers may not get the warning or find it difficult to wake up and get out in the event of dangerous concentration of CO in their homes. This paper presents the development of a smart CO monitoring and control system to control the ventilation in a room when carbon monoxide concentration is at a level dangerous to human health. The system is comprised of a microcontroller interfaced with CO sensor (MQ-7) and ultrasonic distance sensor (HC-SR04) for CO concentration sampling and window state determination respectively. A third component interfaced with the controller is a DC motor, which accordingly control the window when the concentration of CO is high. A mechanism was provided to ensure that the fan in the room is ON and the window is completely open whenever CO concentration is high to ensure quick restoration of the air quality. Results from the performance evaluation of the system showed that it achieved an average response time of 6 seconds and consumed 321.62mW and 652.82mW of power during sampling and control respectively. The obtained results showed that the system is capable of responding quickly to dangerous concentration of CO, thus a desired attribute of CO monitoring systems hence, can adequately replace the existing systems with less power consumption.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smart Home-Control and Monitoring System Using Smart Phone

This paper presents a low cost and flexible home control and monitoring system using an embedded micro-web server, with IP connectivity for accessing and controlling devices and appliances remotely using Android based Smart phone app. The proposed system does not require a dedicated server PC with respect to similar systems and offers a novel communication protocol to monitor and control the ho...

متن کامل

Carbon monoxide and the nervous system.

Carbon monoxide (CO) is a colorless, tasteless, odorless, and non-irritating gas formed when carbon in fuel is not burned completely. It enters the bloodstream through the lungs and attaches to hemoglobin (Hb), the body's oxygen carrier, forming carboxyhemoglobin (COHb) and thereby reducing oxygen (O(2)) delivery to the body's organs and tissues. High COHb concentrations are poisonous. Central ...

متن کامل

Monitoring and Control System of a Separation Column for 13 C Enrichment by Cryogenic Distillation of Carbon Monoxide

Abstract— In incipient stage for laboratory experiments, a monitoring and control based on human operators is usual. Using the acquired experience, a computer monitoring and even control is necessary and possible. In the actual developing plan to apply the cryogenic technology for the production of the C isotope by industrial scale, an efficient and safe operation is a strong reason to conceive...

متن کامل

Carbon Monoxide Sensor for Combustion Feedback Control

A sensor for carbon monoxide detection based on broadband absorption spectroscopy with a gas correlation filter is developed using a miniaturized light source and detector without the need of a mechanical chopper to alternate between two gas correlation cells into the optical path. Measurements were conducted using calibrated CO/N2 mixtures and sampled combustion products from a diffusion flame...

متن کامل

A Microcontroller Based Carbon Monoxide Monitoring and Mapping System Using GPS Technology

Air pollution is a major factor of consideration in the evaluation of quality of life and as an environmental issue in urban areas. Among urban air pollutants carbon monoxide (CO) is one of the most prevalent. Information about its concentrations is vital in the determination of urban air pollution. In this paper, an automatic and cost effective prototype for CO monitoring and mapping is presen...

متن کامل

Intelligent Monitoring System For Carbon Monoxide Poisoning And Leakage In Mines

This paper presents a feasibility study of a wearable helmet in order to protect mine workers specially of goldmines from carbon monoxide poisoning and cyanidation. Carbon monoxide(CO) poisoning is a common problem faced by the workers of coal, gold and many other mines. On the other hand cyanidation problem occurs in gold mines only during ore processing. Current safety systems for mine worker...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 1

صفحات  25- 32

تاریخ انتشار 2020-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023