Sliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
نویسندگان
چکیده مقاله:
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate transformation, and therefore causes a simpler design for power control system. Under unbalanced grid voltage condition, two control targets obtained simultaneously, i.e., removing stator active and reactive power oscillations. Moreover this method reduces the THD of stator current. Also it is shown that the proposed control method not only has a high-speed dynamic response but is stable during wind speed and system parameters variations. Simulation results for a 2kw DFIG confirm prominence of proposed control strategy.
منابع مشابه
Passivity-Based Control of a Doubly Fed Induction Generator System under Unbalanced Grid Voltage Conditions
According to the theory of passivity-based control (PBC), this paper establishes a port-controlled Hamiltonian system with dissipation (PCHD) model for a doubly fed induction generator (DFIG) system under unbalanced grid voltage conditions and proposes a method of interconnection and damping assignment passivity-based control (IDA-PBC) of the system under such conditions. By using this method, ...
متن کاملLow Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage
In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...
متن کاملLoss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate
The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...
متن کاملloss of excitation detection in doubly fed induction generator by voltage and reactive power rate
the doubly fed induction generator (dfig) is one of the most popular technologies used in wind power systems. with the growing use of dfigs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. loss of excitation (loe) event is among the most frequent failures in electric generators. however, loe detection stud...
متن کاملA Novel Doubly-fed Induction Wind Generator Control Scheme for Reactive Power Control and Torque Pulsation Compensation Under Unbalanced Grid Voltage Conditions
Wind energy is often installed in rural, remote areas characterized by weak, unbalanced power transmission grids. In induction wind generators, unbalanced three phase stator voltages cause a number of problems, including overheating and stress on the mechanical components from torque pulsations. Therefore, beyond a certain amount of unbalance (for example 6%), induction wind generators are swit...
متن کاملVSC-based direct torque and reactive power control of doubly fed induction generator
This paper proposes a novel direct torque and reactive power control (DTC) for grid-connected doubly fed induction generators (DFIGs) in the wind power generation applications. The proposed DTC strategy employs a variable structure control (VSC) scheme to calculate the required rotor control voltage directly and to eliminate the instantaneous errors of active and reactive powers without involvi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 3 شماره 2
صفحات 24- 34
تاریخ انتشار 2016-05-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023