Simulation of a Neutron Detector for Real Time Imaging Applications

نویسنده

چکیده مقاله:

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydrogenated amorphous silicon (a-Si:H) diodes would have the optimum characteristics. At a threshold setting of ~7000 electrons, the detectors would have efficiency of about 42%. The expected average signal size is about 12000 electrons, which is well above the noise. These neutron detectors have very low gamma sensitivity and are very well suited to real time neutron imaging applications. A

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Ultrasound Imaging Simulation

This paper introduces UltraSim, a computer-based interactive simulator device designed to train physicians and technicians in medical diagnosis using ultrasound systems. Students using the system are able to learn how to identify and diagnose a wide range of medical cases by operating a simulated ultrasound machine on a mannequin, without any need for actual patients. This application relates t...

متن کامل

a study on thermodynamic models for simulation of 1,3 butadiene purification columns

attempts have been made to study the thermodynamic behavior of 1,3 butadiene purification columns with the aim of retrofitting those columns to more energy efficient separation schemes. 1,3 butadiene is purified in two columns in series through being separated from methyl acetylene and 1,2 butadiene in the first and second column respectively. comparisons have been made among different therm...

Applications of gold nanoparticles for medical imaging

Background & Aim: Molecular imaging enables us to non-invasively visualize tissue microstructures and lesion characterization, allowing accurate diagnosis of diseases at early stages. A successful molecular imaging requires a nontoxic contrast agent with high sensitivity. Nowadays, a wide range of nanoparticles have been developed as contrast agents for medical imaging modalities. Here, we revi...

متن کامل

Real Time Dynamic Simulation of Power System Using Multiple Microcomputers

Recent developments in the design and manufacture of microcomputers together with improved simulation techniques make it possible to achieve the speed and accuracy required for the dynamic simulation of power systems in real time. This paper presents some experimental results and outlines new ideas on hardware architecture, mathematical algorithms and software development for this purpose. The ...

متن کامل

Simulation of Multiprocessor Bus Systems for Real-time Applications

This paper discusses the principles of bus systems simulation for real-time applications. It uses a typical queuing model of a single bus with multiple processors, memories and I/O devices. The major criterion used in evaluation of real-time response is the bus access latency. An illustrative example of a VMEbus system with two arbitration protocols, round-robin and priority-based, for typical ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 11  شماره 4

صفحات  207- 212

تاریخ انتشار 1998-11-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023