Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

نویسندگان

چکیده مقاله:

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accelerator and dose calculation were performed with BEAMnrc and dosxyznrc respectively. The results of simulation were validated by measurements in water by TLD. At 6 MeV and 0.35 cm FWHM, the agreement between dose calculated by Monte Carlo modeling and direct measurement was obtained. The results were accurate and the EGSnrc simulation can be used for dosimetry. After validating this code, it was used to confirm the function of the optical computed tomography system built in the Nuclear Physics Department of the University of Mazandaran. The system used to perform the gel dosimetry independent of other methods such as MRI.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

monte carlo simulation of siemens oncor linear accelerator with egsnrc code

background: the monte carlo method is the most accurate method for simulation of radiation therapy equipment. the linear accelerators are currently the most widely used machines in radiation therapy centers. methods: in this work, a monte carlo modelling of the siemens oncor linear accelerator in 6 mv and 18 mv beams was performed. the results of simulation were validated by measurements in wat...

متن کامل

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

Epp - A C++ Monte Carlo simulation EGSnrc user code for dose calculation and imaging

Epp (Easy particle propagation) is a Monte Carlo simulation EGSnrc user code that we have developed for dose calculation in a voxelized volume, and to generate images for an arbitrary geometry irradiated by a particle source. The dose calculation aspect is a reimplementation of the function of DOSXYZnrc with the performance being significantly improved. The functionality can be readily extended...

متن کامل

Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

BACKGROUND HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computati...

متن کامل

accuracy evaluation of oncentra™ tps in hdr brachytherapy of nasopharynx cancer using egsnrc monte carlo code

background: hdr brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. in this method, depending on how advanced one tumor is, 2 to 6 gy dose as intracavitary brachytherapy is prescribed. due to high dose rate and tumor location, accuracy evaluation of treatment planning system (tps) is particularly important. common methods used in tps dosimetry are based on computat...

متن کامل

Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 4

صفحات  39- 48

تاریخ انتشار 2018-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023