Seismic behavior of semi-dry precast concrete connections using tapered thread couplers

نویسندگان

  • Alireza Khaloo Department of Civil Engineering, Sharif University, Tehran, Iran
چکیده مقاله:

The worldwide use of precast concrete frames leads to an increase in the need for the investigation of efficient precast connections, particularly in the seismic regions. The current paper provides a numerical and experimental study on a dry precast connection. Experiments were conducted to validate the finite element method in the laboratory of the University of Science and Culture. To verify the validity of the result, the outcomes of the non-linear analysis of cross-shaped models were compared with the experimental results in terms of failure mode, ductility, lateral load-bearing capacity, and energy dissipation. The finite element non-linear analyses of the models represented an acceptable compatibility with experimental results. A parametric study has been carried out to survey the effect of the couplers and grout compressive strength on semi-dry connection behavior. Eventually, the response modification factors were determined for the case studies to demonstrate the seismic behavior in design forces. Statistical analysis of the numerical results demonstrates a 6 % increase for response modification factors of the specimens with the closest distance of couples to the column face in relation to those with the couplers farthest away from the column face. Eventually, it can be concluded that the specimens with a shorter coupler distance from the external face of the column and with a higher grout compressive strength lead to the appropriate results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Design Considerations for Precast Concrete Shear Wall Connections

The performance of precast shear wall panel structures subjected to earthquakes relies on the behaviour and integrity of the connections between the panels. The current lack of knowledge on the seismic behaviour of precast wall connections limits the use of such systems in earthquake areas. This paper presents results of an extensive experimental program undertaken at the University of Manitoba...

متن کامل

non-linear seismic behavior of concrete beam - column connections

a parametrik investigation was conducted to study the non-linear behavior of precast and cast-in-place reinforced concrete beam-column connections subjected to tabas seismic forces (1979). the behavior of these types of connections in a four stories structure with respect to strength, ductility , stiffness, and bond deterioration at the joint core are presented and discussed. calculation result...

متن کامل

Design of Hybrid Precast Concrete Walls for Seismic Regions

This paper presents an ongoing research project on the behavior and design of “hybrid” precast concrete wall structures for use in seismic regions. Hybrid precast walls utilize a combination of mild (e.g., Grade 60) steel and high-strength unbonded post-tensioning (PT) steel for flexural resistance across horizontal joints. The mild steel reinforcement is designed to yield in tension and compre...

متن کامل

Predicting the Seismic Behavior of the Dywidag Ductile Connector (DDC) Precast Concrete System

Predicting the Seismic Behavior of the Dywidag Ductile Connector (DDC) Precast Concrete System Elizabeth Mary Kenyon Structural engineering is heavily dependent on the use of computers. When creating a building model using structural analysis software, it is required that the designer have an understanding of the system behavior and the modeling program capabilities. Some engineers in the South...

متن کامل

Seismic Behavior of a Hybrid Precast Concrete Wall Specimen: Measured Response versus Design Predictions

This paper presents the results from the testing of a 0.4-scale “hybrid” precast concrete wall specimen under reversed-cyclic lateral loads combined with gravity loading. The specimen was designed to conform to the requirements of ACI ITG-5.2 (2009) and tested according to ACI ITG-5.1 (2007) to ultimately support the validation of hybrid precast walls for use in moderate and high seismic region...

متن کامل

Seismic Displacement Demands for Hybrid Precast Concrete Shear Walls

This paper presents an analytical investigation on the peak lateral displacement demands of “hybrid” precast concrete panelized shear wall structures under seismic loading. The hybrid wall structure investigated uses a combination of mild [i.e., Grade 400 (U.S. Grade 60)] steel bars and highstrength unbonded post-tensioning (PT) strands for lateral resistance across horizontal joints. The analy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 1

صفحات  11- 20

تاریخ انتشار 2020-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023