Quality enhancement of Pelvis electronic portal images in order to improve treatment accuracy

نویسندگان

  • Amin Asgharzadeh Alvar Department of Biomedical Engineering and Medical Physics Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Hanie Ghaempanah Department of Biomedical Engineering and Medical Physics Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Mohammad Reza Deevband Department of Biomedical Engineering and Medical Physics Shahid Beheshti University of Medical Sciences, Tehran, Iran
  • Mohsen Najafi Shohadaye haftome_tir hospital, Oncology department, Tehran, Iran
چکیده مقاله:

Introduction: In order to reduce patient setup error in treatment field, portal images with treatment beam (megavoltage x-ray) are widely used. These images are acquired by electronic portal imaging devices (EPID). However, portal images suffer from insufficient anatomical information, contrast, and spatial resolution, because of the fact that Compton scatter is the main photon interaction in megavoltage range. The aim of this study is to inspect the efficacy of multiresolution processing method on enhancing quality of these images, which improves the accuracy of the setup verification. Materials and Methods: images of pelvis area were captured which had a low level of quality. Therefore, three major steps are required: contrast enhancement, noise reduction and edge sharpening. A multiresolution processing which can decompose and combine the different scales information are proposed to overcome deficiency of histogram-based enhancement methods. EPID images were decomposed to details and approximation components in order to observe structures in different scales. As a result, the components with highest level of noise and them with bone structure information can be identified. The components can be weighted for reducing the noise and sharpening the edges. Finally modified components are used to reconstruct the enhanced images. Anatomical landmarks in processed images were scored visually by observers in three different levels (physician, physicist and technologist) to qualify the efficacy of the algorithm. Results: The pelvis anatomical landmarks (sacrum, crest of ilium, symphysis, ischium, pubis, acetabulum, sacroiliac joint) were compared by many experts as a quantitative evaluation in terms of their quality, showing the superiority of the processed images. This improvement was reported by all of the experts in different levels, which was mentioned above. Conclusion: it was seen that noise and anatomical structures are separable in different components. The results show that the proposed method in this study significantly improved the quality of portal images, which leads to much more accurate organ localization during radiotherapy of pelvis area.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

A verification procedure to improve patient set-up accuracy using portal images.

The purpose of this study was to establish which level of geometrical accuracy can be obtained during radiotherapy, using portal image analysis, with a minimum number of patient set-up measurements and corrections. A set-up verification and correction procedure using decision rules for improving the set-up of a patient during radiotherapy was investigated by means of a computer simulation. In t...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Explanation of Water Indices and Criteria in the Urban Landscape in Order to Improve the Quality of Urban Environments

Water as one of the most essential natural elements of landscape and consequently urban landscape from yesterday till today has had a great impact on the formation and effectiveness of urban spaces and its various effects have always stimulated human tendency towards beauty. It should be noted that the existential values ​​of water are not merely aesthetic, rather it goes back to the deepest an...

متن کامل

P-93: Understanding The Different KindsFactors of Infertility in Men and Womenin order to Improve The Treatment of Infertility

Background: Infertility in couples who fail to get pregnant after one year of sexual intercourse without contraception is called. approximately 40% of infertility problems in men, 40% women and 10% of androgynous, 10% is unknown. Therefore, the awareness of the different kinds of infertility treatment is effective. Materials and Methods: Study overview, the present Internet search at timescales...

متن کامل

accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (epid)

background: to correct patient positioning errors (setup errors) during prostate cancer treatment using epid and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. materials and methods: fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field imrt planning technique. the p...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  293- 293

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023