Pool boiling heat transfer coefficient of pure liquids using dimensional analysis
نویسندگان
چکیده مقاله:
The pool boiling heat transfer coefficient of pure liquids were experimentally measured on a horizontal bar heater at atmospheric pressure. These measurements were conducted for more than three hundred data in thermal currents up to 350 kW.m-2. Original correlations and the unique effect of these correlations on experimental data were discussed briefly. According to the analysis, a new empirical relationship implying a performance superior to other available correlations is presented.
منابع مشابه
Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...
متن کاملexperimental investigation in pool boiling heat transfer of pure/binary mixtures and heat transfer correlations
nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. in this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in pure ...
متن کاملPool Boiling Heat Transfer in Water/Amines Solutions
In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...
متن کاملAnalysis of pool boiling heat transfer over porous surfaces
A semi-empirical model for pool boiling over porous surfaces is presented. The pressure drop across the porous surface is estimated using Darcy 's law. The signi®cance of the latent heat ̄ux contribution for highly porous surfaces is examined. Two nucleation factors are de®ned and correlated in terms of measurable quantities using literature data. An expression for the total heat ̄ux in terms o...
متن کاملHeat transfer in nucleate pool boiling of multicomponent mixtures
Steady state pool boiling heat transfer coefficients have been obtained experimentally for acetone–isopropanol–water and acetone–MEK (methyl ethyl ketone)–water ternary systems. The data show that, for a given heat flux, the heat transfer coefficients of mixtures are lower than those obtained for pure components constituting the mixture. The measured heat transfer coefficients were compared wit...
متن کاملPool Boiling Heat Transfer Characteristics of Nanofluids by Sung Joong
Nanofluids are engineered colloidal suspensions of nanoparticles in water, and exhibit a very significant enhancement (up to 200%) of the boiling Critical Heat Flux (CHF) at modest nanoparticle concentrations (50.1% by volume). Since CHF is the upper limit of nucleate boiling, such enhancement offers the potential for major performance improvement in many practical applications that use nucleat...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 3 شماره 2
صفحات 63- 69
تاریخ انتشار 2017-07-31
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023