POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
نویسندگان: ثبت نشده
چکیده مقاله:
Polarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. A value of 25?C/cm2 is measured for the saturated polarization from the hysteresis curve. The polarization retention is also measured at 200°C for the device and the polarization change over 24 hours was about 5.7%.
منابع مشابه
polarization hysteresis curve measurement for an au/pzt/ybco device by double pulse technique
polarization for au/pb(zr ti )o /yba cu o ferroelectric capacitor has been studied and measured by pulse method. a sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. a value of 25?c/cm2 is measured for the saturated p...
متن کاملHighly simplified device for ultrashort-pulse measurement.
We show that a frequency-resolved optical gating device using (1) a thick nonlinear crystal to replace the usual thin crystal and spectrometer and (2) a Fresnel biprism to replace the beam splitter and delay line yields a remarkably simple single-shot ultrashort-pulse intensity-and-phase measurement device with no sensitive alignment parameters and significantly greater sensitivity.
متن کاملThe Differentiating Polarization Curve Technique for the Tafel Parameter Estimation
An experimentally obtained polarization curve for the hydrogen evolution reaction on silver in a 0.5 mol dm−3 solution was investigated using an electrochemical curve technique named the differential polarization method (DPM). The exchange current density estimated by the Tafel extrapolation method (TEM) and the DPM were compared and assessed from points of simple and more accurate handling. It...
متن کاملOn the Transmission Line Pulse Measurement Technique
Transmission Line Pulse is a short pulse (25ns to 150ns) measurement of the current-voltage (I/V) characteristics of the ESD protection built into an integrated circuit. The short TLP pulses are used to simulate the short ESD pulse threats and integrated circuit must tolerate without being damaged. In this work the fundamental principles of how the TLP pulse is generated and used to create I-V ...
متن کاملHysteresis in Lanthanide Aluminum Oxides Observed by Fast Pulse CV Measurement
Oxide materials with large dielectric constants (so-called high-k dielectrics) have attracted much attention due to their potential use as gate dielectrics in Metal Oxide Semiconductor Field Effect Transistors (MOSFETs). A novel characterization (pulse capacitance-voltage) method was proposed in detail. The pulse capacitance-voltage technique was employed to characterize oxide traps of high-k d...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 9 شماره 2
صفحات -
تاریخ انتشار 1998-06-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023