Photon dosimetry based on selective data sampling for the NaI(TL) detector

نویسندگان

چکیده مقاله:

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is trying to create relevance and proportionality between detector readout and value of the dose equivalent. For this purpose, there are various software methods and hardware methods are obtained dose equivalent values. Software methods such as convolution, Deconvolution, etc. and hardware methods such as additional of layers of modulators, etc have been used. Selective data sampling of multi-channel energy is a software method which has been studied in this paper. The main purpose of this method, is obtaining the response of photon dosimetry at different energies. The response function of NaI(TL) 3”×3” detector for 0.411 MeV to 3 MeV gamma-rays has been simulated by using MCNPX code, and for calculating dose, the calibration coefficients were determined. Finally, the response energy of the detector has been drawn for photon dosimetry of the channels with multiple energy range. Results show that presented dosimety method has high level precision. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Sampling on Probabilistic Data

In the literature of supervised learning, most existing studies assume that the labels provided by the labelers are deterministic, which may introduce noise easily in many real-world applications. In many applications like crowdsourcing, however, many labelers may simultaneously label the same group of instances and thus the label of each instance is associated with a probability. Motivated by ...

متن کامل

developing a pattern based on speech acts and language functions for developing materials for the course “ the study of islamic texts translation”

هدف پژوهش حاضر ارائه ی الگویی بر اساس کنش گفتار و کارکرد زبان برای تدوین مطالب درس "بررسی آثار ترجمه شده ی اسلامی" می باشد. در الگوی جدید، جهت تدوین مطالب بهتر و جذاب تر، بر خلاف کتاب-های موجود، از مدل های سطوح گفتارِ آستین (1962)، گروه بندی عملکردهای گفتارِ سرل (1976) و کارکرد زبانیِ هالیدی (1978) بهره جسته شده است. برای این منظور، 57 آیه ی شریفه، به صورت تصادفی از بخش-های مختلف قرآن انتخاب گردید...

15 صفحه اول

Preliminary Dosimetry Study of 67Ga-AATS for Human Based on Biodistribution Data in Rats

Introduction Gallium-67 (67Ga) has been used as a radionuclide for imaging a variety of solid tumors since 1969. Since then use of various gallium-based radiotracers has been reported. Recently, 67Ga-labeled acetylacetate bis(thiosemicarbazones) (67Ga-AATS) complex with significant tumor accumulation and fast blood clearance has been employed. Materials and Methods In this study, the absorbed d...

متن کامل

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

Air Kerma Based Dosimetry versus Absorbed Dose to Water Based Dosimetry for High-energy Photon

Introduction: In the last 5 years the American Association of Physicists in Medicine Task Group 51 (AAPM TG-51) and the International Atomic Energy Agency (IAEA) published a new high-energy photon and electron dosimetry protocol. These protocols are based on the use of an ion chamber having an absorbed-dose to water calibration factor. These are different from the previous NCS report-2 and IAEA...

متن کامل

Up-conversion single-photon detector using multi-wavelength sampling techniques.

The maximum achievable data-rate of a quantum communication system can be critically limited by the efficiency and temporal resolution of the system's single-photon detectors. Frequency up-conversion technology can be used to increase detection efficiency for IR photons. In this paper we describe a scheme to improve the temporal resolution of an up-conversion single-photon detector using multi-...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  191- 196

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023