Performance Evaluation of a Ranque-Hilsch Vortex Tube with Optimum Geometrical Dimensions

نویسندگان

  • Fatolah Farhadi Department of Chemical and Petrochemical Engineering, Sharif University of Technology, Tehran, I.R. IRAN
  • Samira Mohammadi Department of Chemical and Petrochemical Engineering, Sharif University of Technology, Tehran, I.R. IRAN
چکیده مقاله:

 A brass Vortex Tube (VT) with interchangeable parts is used to determine the optimum cold end orifice diameter, main tube length and diameter. Experiments were carried out to study the effects of operating pressure as well. It is shown that there is an optimum value for cold end orifice diameter, which is equal to 4mm and there is an optimum value for cold and hot exit temperature difference at CF=0.4.A 2-D Computational Fluid Dynamics (CFD) model is validated against the present experimental data. CFD code is applied to investigate the role of vortex tube diameter and length on the temperature separation. The code is also used to investigate and analyze the highly rotating flow field structure and its characteristic with respect to various cold fractions. Finally the results are extrapolated for investigating the effect of inlet pressures up to 1053kPa, VT on separation performances.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

performance evaluation of a ranque-hilsch vortex tube with optimum geometrical dimensions

a brass vortex tube (vt) with interchangeable parts is used to determine the optimum cold end orifice diameter, main tube length and diameter. experiments were carried out to study the effects of operating pressure as well. it is shown that there is an optimum value for cold end orifice diameter, which is equal to 4mm and there is an optimum value for cold and hot exit temperature difference at...

متن کامل

Maxwell's demon in the Ranque-Hilsch vortex tube.

A theory was developed that explains energy separation in a vortex tube, known as one of the Maxwellian demons. It appears that there is a unique relation between the pressures in the exits of the vortex tube and its temperatures. Experimental results show that the computed and measured temperatures are in very good agreement.

متن کامل

Experimental Evaluation of a Ranque- Hilsch Vortex Tube as a Particle Separator

R & D Journal of the South African Institution of Mechanical Engineering 2012,28,25-30 http://www.saimeche.org.za (open access) © SAIMechE All rights reserved. 25 The Pebble Bed Modular Reactor (PBMR) is a Generation IV graphite-moderated helium cooled nuclear reactor developed in South Africa from the German Arbeitsgemeinschaft Versuchreaktor (AVR). After decommissioning of the AVR plant, radi...

متن کامل

2D Numerical Simulation of a Micro Scale Ranque-Hilsch Vortex Tube

  In this study, fluid flow and energy separation in a micro-scale Ranque-HilschVortex Tube are numerically investigated. The flow is assumed as 2D, steady,compressible ideal gas, and shear-stress-transport SST k-W is found to be a bestchoice for modeling of turbulence phenomena. The results are in a good agreementwith the experimental results reported in the literature. The results show that f...

متن کامل

A new approach to selective brain cooling by a Ranque-Hilsch vortex tube

BACKGROUND Target temperature management is the single most effective intervention and the gold standard in post-resuscitation care today. However, cooling the whole body below 33-34 °C can cause severe complications. Therefore, developing a selective brain cooling (SBC) approach which can be initiated early to induce rapid cooling and maintain the target temperature over 12-24 h before slowly ...

متن کامل

Review of Ranque–Hilsch effects in vortex tubes

The vortex tube or Ranque–Hilsch vortex tube is a device that enables the separation of hot and cold air as compressed air flows tangentially into the vortex chamber through inlet nozzles. Separating cold and hot airs by using the principles of the vortex tube can be applied to industrial applications such as cooling equipment in CNC machines, refrigerators, cooling suits, heating processes, et...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 35  شماره 1

صفحات  95- 107

تاریخ انتشار 2016-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023