Optimal Thermal Unit Commitment Solution integrating Renewable Energy with Generator Outage

نویسندگان

  • N. Murali Krishnan Department of Electrical and Electronics Engineering, Mailam Engineering College, Tamil Nadu, India
  • R. K. Santhi Department of Electrical Engineering, Annamalai University, Tamil Nadu, India.
  • S. Ganesan Department of Electrical and Electronics Engineering, Government College of Engineering, Tamil Nadu, India
  • S. Sivasakthi Department of Electrical and Electronics Engineering, Krishnasamy College of Engineering and Technology, Tamil Nadu, India.
  • S. Subramanian Department of Electrical Engineering, Annamalai University, Tamil Nadu, India.
چکیده مقاله:

The increasing concern of global climate changes, the promotion of renewable energy sources, primarily wind generation, is a welcome move to reduce the pollutant emissions from conventional power plants. Integration of wind power generation with the existing power network is an emerging research field. This paper presents a meta-heuristic algorithm based approach to determine the feasible dispatch solution for wind integrated thermal power system. The Unit Commitment (UC) process aims to identify the best feasible generation scheme of the committed units such that the overall generation cost is reduced, when subjected to a variety of constraints at each time interval. As the UC formulation involves many variables and system and operational constraints, identifying the best solution is still a research task. Nowadays, it is inevitable to include power system reliability issues in operation strategy. The generator failure and malfunction are the prime influencing factor for reliability issues hence they have considered in UC formulation of wind integrated thermal power system. The modern evolutionary algorithm known as Grey Wolf Optimization (GWO) algorithm is applied to solve the intended UC problem. The potential of the GWO algorithm is validated by the standard test systems. Besides, the ramp rate limits are also incorporated in the UC formulation. The simulation results reveal that the GWO algorithm has the capability of obtaining economical resolutions with good solution quality.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal unit commitment of renewable energy sources in the micro-grids with storage devices

In this work; we suggest a new intelligent optimization method to solve the optimal energy management issue in the renewable micro-grids (MGs). The proposed method is constructed based on the harmony search (HS) algorithm as well as a novel adaptive modification method to solve the problem effectively. The proposed modification method consists of three submodifications to provide the algorithm ...

متن کامل

Thermal Unit Commitment Strategy Integrated with Solar Energy System

This paper presents a methodology for solving unit commitment problem for thermal units integrated with solar energy system. The Solar energy source is included in this model due to low electricity cost and environmental issues like Global warming, Greenhouse effect, etc., There will be changes in the generation cost by considering the solar energy and this paper explains about the differences ...

متن کامل

Thermal Unit Commitment Solution Using an Improved Lagrangian Relaxation

An improved Lagrangian relaxation (LR) solution to the thermal unit commitment problem (UCP) is proposed in this paper. The algorithm is characterized by: (1) a new Matlab function to determine the optimal path of the dual problem, (2) new initialization procedure of Lagrangian multipliers, based on both unit and time interval classification, (3) a flexible adjustment of Lagrangian multipliers,...

متن کامل

Wind Integrated Thermal Unit Commitment Solution using Grey Wolf Optimizer

Received Dec 24, 2016 Revised Apr 26, 2017 Accepted Jun 14, 2017 The augment of ecological shield and the progressive exhaustion of traditional fossil energy sources have increased the interests in integrating renewable energy sources into existing power system. Wind power is becoming worldwide a significant component of the power generation portfolio. Profuse literatures have been reported for...

متن کامل

Thermal Unit Commitment Including Optimal AC Power Flow Constraints

We propose a new algorithm for unit commitment that employs a Lagrange relaxation technique with a new augmentation of the Lagrangian. The new augmentation involves a duplication of variables that allows relaxation of the coupling between generator timespanning constraints and system-wide instantaneous constraints. This framework allows the possibility of committing units that are required for ...

متن کامل

Artificial Intelligence Based Thermal Unit Commitment and Optimal Generation Scheduling

An efficient Unit Commitment (UC) plays an important role in the economic operation of a power system. The generation planning mainly concerns with the short-term generation scheduling, i.e. unit commitment, which determines the optimal set of generating units to be used over a time horizon of a day or a week. The UC problem has commonly been formulated as a nonlinear, large-scale, mixed-intege...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  112- 122

تاریخ انتشار 2017-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023