Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry
نویسندگان
چکیده مقاله:
Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used for polymer gel dosimetry in radiation therapy were prepared. Using a laboratory spectrophotometer, light absorbance against wavelength of light spectrum from 400 to 700 nm was measured. The optical absorbance-dose response curves were obtained for different wavelengths and the results were compared to find the wavelength where the highest sensitivity of polymer gels is occurred. Results The results showed light wavelength dependency for polymer gels optical absorbance-dose sensitivity. The highest sensitivity was seen in the blue part of visible light at wavelengths of 440 and 460 nm for PAGAT and NIPAM, respectively. Moreover, the sensitivity of NIPAM gel was higher than PAGAT for all studied wavelengths. Conclusion The sensitivity of both gels varied considerably with light wavelength and was higher in shorter wavelength of visible light. It is recommended to study optical absorbance-dose sensitivity of polymer gels for selecting the optimum light wavelength for optical measurements and optical computed tomography applications.
منابع مشابه
optical characterization of nipam and pagat polymer gels for radiation dosimetry
introduction the purpose of the current study was to determine optical sensitivity of n-isopropyl acrylamide nipam and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (pagat) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. materials and methods nipam and pagat polymer gels with conventional formulations used f...
متن کاملThree dimensional radiation dosimetry using polymer gels
The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...
متن کاملRadiation dosimetry using polymer gels: methods and applications.
New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and appli...
متن کاملstudy and characterization of fiber optical gyroscope مطالعه و مشخصه یابی ژیروسکوپ فیبر نوری(تار نوری)
ژیروسکوپ فیبر نوری fog بر اساس پدیده تداخل ساگنام دو پرتو لیزری از یک فیبر نوری بسیار طولانی داده های لازم را فراهم می آورد
15 صفحه اولOptical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry.
BACKGROUND Application of less toxic normoxic polymer gel of N-isopropyl acrylamide (NIPAM) for radiation therapy has been studied in recent years. AIM In the current study the optical and NMR properties of NIPAM were studied for radiation therapy dosimetry application. MATERIALS AND METHODS NIPAM normoxic polymer gel was prepared and irradiated by 9 MV photon beam of a medical linac. The o...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 11 شماره 1
صفحات 188- 194
تاریخ انتشار 2014-03-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023