Newborn EEG Seizure Detection Based on Interspike Space Distribution in the Time-Frequency Domain

نویسندگان

  • M. Mesbah School of Medicine, University of Queensland
چکیده مقاله:

This paper presents a new time-frequency based EEG seizure detection method. This method uses the distribution of interspike intervals as a criterion for discriminating between seizure and nonseizure activities. To detect spikes in the EEG, the signal is mapped into the time-frequency domain. The high instantaneous energy of spikes is reflected as a localized energy in time-frequency domain. Histogram of successive spikes intervals is then used as a feature for seizure detection. In the presented technique the EEG data are segmented into 4-second epochs. A k-nearest neighbor algorithm is employed to classify the EEG epochs into seizure and nonseizure groups. The performance of the presented technique is evaluated using the EEG data of five neonates. The results indicate that the proposed technique is superior to the other existing methods with 92.4 % good detection rate and 4.9 % false detection rate.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Newborn EEG Seizure Detection Using Adaptive Time-Frequency Signal Processing

D ysfunction in the central nervous system of the neonate is often rst identi ed through seizures. The di culty in detecting clinical seizures, which involves the observation of physical manifestations characteristic to newborn seizure, has placed greater emphasis on the detection of newborn electroencephalographic (EEG) seizure. The high incidence of newborn seizure has resulted in considerabl...

متن کامل

Instantaneous frequency based newborn EEG seizure characterisation

The electroencephalogram (EEG), used to noninvasively monitor brain activity, remains the most reliable tool in the diagnosis of neonatal seizures. Due to their nonstationary and multi-component nature, newborn EEG seizures are better represented in the joint time–frequency domain than in either the time domain or the frequency domain. Characterising newborn EEG seizure nonstationarities helps ...

متن کامل

Newborn EEG seizure pattern characterisation using time-frequency analysis

Previous techniques for seizure detection in newborn are inefficient. The main reason for their relative poor performance resides in their assumption of stationarity of the EEG. To remedy this problem, we use time-frequency distributions (TFD) to analyse and characterise the newborn EEG seizure patterns as a first step toward a time-frequency (TF) based seizure detection and classification sche...

متن کامل

Time-Frequency Feature Extraction of Newborn EEG Seizure Using SVD-Based Techniques

The nonstationary and multicomponent nature of newborn EEG seizures tends to increase the complexity of the seizure detection problem. In dealing with this type of problems, time-frequency-based techniques were shown to outperform classical techniques. This paper presents a new time-frequency-based EEG seizure detection technique. The technique uses an estimate of the distribution function of t...

متن کامل

The frequency of EEG abnormalities in children with febrile seizure

Background and Objective: Febrile seizures are one of the most common neurological disorders in children. The aim of this study was to investigate the extent of abnormal EEG reports and their association with other risk factors of febrile seizures. Material &Method: In this prospective observational study, all patients with febrile seizure admitted in Mousavi Hospital in Zanjan, Iran, from Ap...

متن کامل

Automatic seizure detection based on the combination of newborn multi-channel EEG and HRV information

This article proposes a new method for newborn seizure detection that uses information extracted from both multi-channel electroencephalogram (EEG) and a single channel electrocardiogram (ECG). The aim of the study is to assess whether additional information extracted from ECG can improve the performance of seizure detectors based solely on EEG. Two different approaches were used to combine thi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 20  شماره 2

صفحات  137- 146

تاریخ انتشار 2007-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023