Modified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1
نویسندگان
چکیده مقاله:
Background: Distal humeral fractures accounts for approximately 2% of all fractures and nearly one-third of humeralfractures in adults. In this regard, Modified Tension Bind Wiring (MTBW) technique was used for the fixation of the distalhumeral fractures type A2 and C1 (AO) to evaluate the early movement and complications of the patients.Methods: This study was conducted on 25 patients, who were subjected to open reduction and internal fixation usingMTBW techniques, to evaluate the incidence of complications.Results: The mean age of the participants was 53.7 years. Out of 25 patients, 16 cases had C1 and 6 individualssuffered from A2. The mean tourniquet time was 43 min. The mean union time was 12.24 weeks and the mean durationof the follow-ups was 13.72 months. The mean values for the lack of extension, flexion, and range of motion were 18o,124o, and 106o, respectively. Wound haematoma and dehiscence were observed in two cases, who were treated afterconservative treatment. During 15-90 days, there were no signs of neurapraxia injuries. The non-union of olecranonosteotomy site was seen in one case, who was treated by the MTBW technique. Since the range of motion was lessthan 100o in 4 patients, device removal was performed 6 months after the surgery when the range of motion wasincreased by nearly 12o. Moreover, patients were diagnozed with no serious complications, such as the nonunion offracture site, malunions, and deep infection. The radiological examination of the patients revealed the success of theirtreatment.Conclusion: Based on the obtained results, it can be concluded that MTBW is an effective technique in fracturefixation, which allows gentle early motion. Moreover, this cost-effective technique decreased the surgery duration,tourniquet time, and damage caused by soft tissue stripping.Level of evidence: IV
منابع مشابه
Percutaneous Tension-Band Suture Technique for Distal Patella Fracture Fixation
MOJ Orthop Rheumatol 2017, 8(3): 00315 reported rates up to 60 % [3,8,9]. For this reason, some have advocated the use of nonabsorbable sutures such as braided polyester, lowering the rate of revision surgery secondary to symptomatic hardware [3,10-14]. Studied suture material has included number 5 Ethibond (Ethicon, Somerville, NJ, USA), number 5 Ti-Cron (Davis and Geck, Gosport, Hampshire, UK...
متن کاملPercutaneous tension band wiring for patellar fractures.
PURPOSE To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. METHODS 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. RESULTS 20 patients underwent suc...
متن کاملOlecranon Process Fracture in a Radial Club Hand Treated with Tension Band Wiring: A Case Report
INTRODUCTION Radial club hand is rare deformity, and many patients do not receive treatment due to lack of awareness. None of the treatment options available can restore normality. Fractures of the olecranon process in radial club hand are rare probably due to limited use of the limb. CASE REPORT We report the case of a 35-year-old male with radial club hand who presented with a transverse fr...
متن کاملManagement of heterotopic ossification and restricted forearm rotation after tension band wiring for olecranon fracture
A 32-year-old lady presented to our clinic with persistent painful restriction of her dominant forearm movements for three months after tension band wiring of olecranon. She had full elbow flexion and extension; however, her forearm rotations were restricted and painful. Investigations revealed prominent tips of the wire, eroding the radial tuberosity with heterotopic ossification between the r...
متن کاملMalpositioned olecranon fracture tension-band wiring results in proximal radioulnar synostosis
BACKGROUND Tension-band wiring (TBW) is a well-established fixation technique for two-part, transverse fracture types of the olecranon. However, complication rates up to 80 % are reported. By reporting on the enormous impact on the patient if failed the aim of the present report was to emphasize the importance of correct K wire positioning in TBW. CASE PRESENTATION We present the case of a 49...
متن کاملTension band wiring versus Knowles pinning for non-union of type-2 distal clavicle fractures.
UNLABELLED PURPOSE; To compare tension band wiring (TBW) with Knowles pinning for non-union of type-2 distal clavicle fractures. METHODS 22 men and 6 women aged 23 to 62 (mean, 39) years underwent TBW (n=17) or Knowles pinning (n=11) for non-union of type-2 distal clavicle fractures. Both techniques were supplemented with autogenic cancellous bone grafting. Functional outcome of the shoulder ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 7 شماره 4
صفحات 325- 330
تاریخ انتشار 2019-07-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023