Iterative Approach for Automatic Beam Angle Selection in Intensity Modulated Radiation Therapy Planning
نویسندگان
چکیده مقاله:
Introduction: Beam-angle optimization (BAO) is a computationally intensive problem for a number of reasons. First, the search space of the solutions is huge, requiring enumeration of all possible beam orientation combinations. For example, when choosing 4 angles out of 36 candidate beam angles, C36 = 58905 possible combinations exist. Second, any change in a beam 4 configuration requires re-calculation and re-optimization of intensity maps, itself a time- consuming process. Third, many local minima (maxima) will appear in the objective function. This paper introduces a new framework to beam-angle selection in intensity modulated radiation therapy (IMRT). Materials and Methods: In the proposed algorithm for beam angle selection, the problem is solved in two iterative steps: (1) For all beam that given in search space, the fluence map optimization is done to minimize an objective function that is based on clinical requirement and then used to scoring each beam direction. (2) the proposed algorithm is eliminated an insignificant beam angle (with the lowest score in step one) from search poll in each iteration until the beam selection algorithm is received to the predefined number of angles to be used for the treatment. To accelerate each iteration of dose calculation, dose matrix was precalculated in which the dose deposited in voxel i by an IMRT beam is given by Di = ∑ Kimxm where xm is the weight for the mth beamlet. the efficiency of the algorithm was examined in two clinical cases (TG- 119 phantom and prostate case) in terms of DVH and dose distribution. In all cases, the judgment of the algorithm’s efficiency was based on the comparison between plans with equi-spaced beams and plans with beams obtained using the algorithm. Results: the beam selecting framework has been tested for both a simulated and clinical case(prostate), and the results show the target coverage and dose uniformity remains essentially unchanged, the mean and maximum dose of OARs is significantly decrease as a result of beam selection. For example, in prostate case, the mean dose of rectum and bladder reduced 10.2% and 7.6% respectively. Moreover, D95 of bladder decreased from 10.13 Gy in equiAngular beam selection to 20.3 Gy by the automatic beam angle selection. Conclusion:This study demonstrates that the algorithm can be effectively applied to IMRT scenarios to get case specific beam angle configurations.
منابع مشابه
Iterative Solution Methods for Beam Angle and Fluence Map Optimization in Intensity Modulated Radiation Therapy Planning
We present computational approaches for optimizing beam angles and fluence maps in Intensity Modulated Radiation Therapy (IMRT) planning. We assume that the number of angles to be used for the treatment is given by the treatment planner. A mixed integer programming (MIP) model and a linear programming (LP) model are used to find an optimal set of beam angles and their corresponding fluence maps...
متن کاملA hybrid approach to beam angle optimization in intensity-modulated radiation therapy
Intensity-Modulated Radiation Therapy is the technique of delivering radiation to cancer patients by using non-uniform radiation fields from selected angles, with the aim of reducing the intensity of the beams that go through critical structures while reaching the dose prescription in the target volume. Two decisions are of fundamental importance: to select the beam angles and to compute the in...
متن کاملA matheuristic approach to solve the multiobjective beam angle optimization problem in intensity-modulated radiation therapy
Selecting a suitable set of beam angles is an important but difficult task in intensity modulated radiation therapy (IMRT) for cancer treatment. From a single objective point of view this problem, known as beam angle optimisation (BAO) problem, is solved by finding a beam angle configuration (BAC) that leads to the best dose distribution, according to some objective function. Because there exis...
متن کاملA method for standardizing intensity modulated radiation therapy planning optimization for nasopharyngeal carcinoma
Background: To investigate a method for standardizing intensity modulated radiation therapy (IMRT) optimization for nasopharyngeal carcinoma (NPC), in order to reduce the influence of subjective factors. Materials and Methods: This study is based on example IMRT plans for NPC, which were randomly divided into data acquisition and data verification groups. Organs at risk (OARs) were analyzed for...
متن کاملProton-Beam vs Intensity-Modulated Radiation Therapy
June 01, 2008 External-beam radiation is a highly effective curative treatment option for men with localized prostate cancer.[1,2] Over the past several decades, efforts have been made to improve the “therapeutic ratio” of radiation by increasing dose to improve cure rates without causing a substantial increase in side effects. Due to its potential to create superior dose distributions, proton ...
متن کاملA Response Surface Approach to Beam Orientation Optimization in Intensity-Modulated Radiation Therapy Treatment Planning
W view the beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning as a global optimization problem with expensive objective function evaluations. We propose a response surface method that, in contrast with other approaches, allows for the generation of problem data only for promising beam orientations as the algorithm progresses. This enab...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 203- 203
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023