Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

نویسندگان

  • H Afarideh
  • S J HosseiniAliabadi
  • S M Hosseini Pooya
چکیده مقاله:

Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area.Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry.Method: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval.Result: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method.Conclusion: This system can be utilized in large scale environmental monitoring with a higher accuracy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

improvement of accuracy in environmental dosimetry by tld cards using three-dimensional calibration method

normal 0 false false false en-us x-none fa background: the angular dependency of response for tld cards may cause deviation  from its true value on the results of environmental dosimetry, since tlds may  be exposed to radiation at different angles of incidence from the surrounding area. objective: a 3d setting of tld cards has been calibrated isotropically in a standard  radiation field to eval...

متن کامل

Comparison of TLD calibration methods for  192Ir dosimetry

For the purpose of dose measurement using a high-dose rate (192)Ir source, four methods of thermoluminescent dosimeter (TLD) calibration were investigated. Three of the four calibration methods used the (192)Ir source. Dwell times were calculated to deliver 1 Gy to the TLDs irradiated either in air or water. Dwell time calculations were confirmed by direct measurement using an ionization chambe...

متن کامل

Accuracy Improvement in Camera Calibration

Camera calibration is a necessary and critical step in 3D object analysis. The accuracy of calibration results will affect the object’s position in world coordinates, especially for 3D object tracking. In this paper, we present a new camera calibration approach, and discuss its accuracy. We use 3D marks instead of 2D marks for calibration. Our experimental results show that our approach has the...

متن کامل

Three dimensional radiation dosimetry using polymer gels

The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 2

صفحات  -

تاریخ انتشار 2015-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023