Identifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test

نویسندگان

  • Amirhosein Mirafzal Department of Emergency Medicine, Kerman University of Medical Sciences, Kerman, Iran
  • Leyli Asadabadi Department of Emergency Medicine, Kerman University of Medical Sciences, Kerman, Iran
  • Mohmmad Mehdy Heiran Department of Emergency Medicine, Kerman University of Medical Sciences, Kerman, Iran
چکیده مقاله:

Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. All patients with diagnostic or therapeutic paracentesis of ascitic fluid were considered as eligible patients. Exclusion criteria included clinical suspicion for spontaneous bacterial peritonitis (SBP), any contraindications to paracentesis, and patients’ refusal to participate in the study. Dipstick values were obtained at the bedside, and SAAG was calculated after the determination of serum and ascitic fluid albumin by laboratory. A low SAAG ascitic fluid was defined as the study outcome. We also used our study population as a test group to evaluate an equation proposed in one previous study: K = 0.012 Protein−0.012 Glucose−3.329 pH+23.498 Results: A total of 50 patients were enrolled in the study. Based on multivariate regression analysis, dipstick values for protein and glucose were independently predictive of a low SAAG ascitic fluid (P = 0.23, OR = 1.04; and P = 0.001, OR = 0.81, respectively). The formula proposed in one of the previous studies was tested by our data set, with sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) at 84%, 83%, 84%, and 80%, respectively. Conclusion: Dipstick test of ascitic fluid for pH, glucose, and protein has an acceptable sensitivity and specificity as a point of care test, but it cannot be recommended as a substitute for SAAG determination based on the current findings.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

identifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test

objective: to evaluate the capability of ascitic fluid dipstick results for ph, glucose, and protein in order to predict a low serum-ascites albumin gradient (saag) at the bedside of the patient in the emergency department (ed). methods: this prospective cross-sectional study was conducted during one year in the ed of afzalipour hospital in kerman, iran. all patients with diagnostic or therapeu...

متن کامل

Analysis of Serum Ascites Albumin Gradient Test in Ascitic Dogs

The aim of the study was to evaluate Serum Ascites Albumin Gradient (SAAG) in ascitic dogs. Study was conducted at Referral Veterinary Poly Clinic, Indian Veterinary Research Institute, Izatnagar. Sick dogs were brought with clinical signs suggestive of distended abdomen and inappetance. General clinical examination, biochemical, ultrasound examination, abdominocentesis and peritoneal fluid exa...

متن کامل

New proposal for the serum ascites albumin gradient cut-off value in Chinese ascitic patients

BACKGROUND Serum ascites albumin gradient (SAAG) has been recognized as a reliable marker in the differential diagnosis of ascites. The etiological background of cirrhosis is rather different between western countries and eastern countries. The threshold of SAAG in Chinese ascitic patients has not been evaluated yet. The aim of this study was to define a new reasonable threshold of SAAG in Chin...

متن کامل

Comparative utility of sero ascites albumin gradient and ascitic fluid total protein for differential diagnosis of ascites.

Ascites can be defined as the abnormal accumulation of fluid inside the peritoneal cavity. Earlier ascites was classified as transudative and exudative based on the total protein concentration of the ascitic fluid. The traditional concept of high protein ascites(> 2.5 g/dl) as exudate was questioned because: (a) the normal peritoneal fluid protein concentration is some times > 4 g/dl(1); (b) th...

متن کامل

Retraction Note: New proposal for the serum ascites albumin gradient cut-off value in Chinese ascitic patients

Retraction The Publisher and Editor regretfully retract this article [1] because the peer-review process was inappropriately influenced and compromised. As a result, the scientific integrity of the article cannot be guaranteed. A systematic and detailed investigation suggests that a third party was involved in supplying fabricated details of potential peer reviewers for a large number of manusc...

متن کامل

Role of laparoscopy in the diagnosis of low serum ascites albumin gradient.

The objective is to determine causes of low serum ascites albumin gradient (SAAG) by direct visualization and obtaining biopsy samples using laparoscopic technique. This is a hospital-based, observational study conducted at Department of Gastroenterology, Sheikh Zayed Hospital, Lahore from January 2001 to April 2002. A total of 33 patients with ascites (SAAG < 1.1 g/dl)) were selected. The find...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 1

صفحات  7- 10

تاریخ انتشار 2016-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023