High-performance and Low-power Clock Branch Sharing Pseudo-NMOS Level Converting Flip-flop

نویسندگان

  • Kapil Juneja Electronics & Communications Engineering, National Institute of Technology Kurukhshetra
  • N.P. Singh Electronics & Communications Engineering, National Institute of Technology Kurukhshetra
  • Yateesh Sharma Electronics & Communications Engineering, National Institute of Technology Kurukhshetra
چکیده مقاله:

Multi-Supply voltage design using Cluster Voltage Scaling (CVS) is an effective way to reduce power consumption without performance degradation. One of the major issues in this method is performance and power overheads due to insertion of Level Converting Flip-Flops (LCFF) at the interface from low-supply to high-supply clusters to simultaneously perform latching and level conversion. In this paper, an improved version of clocked pseudo-NMOS LCFF called Clock Branch Sharing pseudo-NMOS LCFF has been proposed, which combines the Conditional Discharge technique, pseudo-NMOS technique and Clock Branch Sharing technique. Based on Simulation results, the proposed flip-flop exhibits up to 32.5% delay reduction and saves power up to 8.1% as compared to clocked pseudo-NMOS LCFF.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High - performance and Low - power Clock Branch Sharing Pseudo - NMOS Level

Multi-supply voltage design using Cluster Voltage Scaling (CVS) is an effective way to reduce power consumption without performance degradation. One of the major issues in this method is performance and power overhead due to insertion of Level Converting Flip-Flops (LCFF) at the interface from lowsupply to high-supply clusters to simultaneously perform latching and level conversion. In this pap...

متن کامل

A Low-Power Level-Converting Double-Edge-Triggered Flip-Flop Design

This paper proposes a new double-edge-triggered implicitly level-converting flip-flop, suitable for a low-power and low-voltage design. The design employs a sense amplifier architecture to reduce the delay and power consumption. Experimentally, when implemented with a 130-nm, single-Vt and 0.84 V VDD process, it achieves 64% power-delay product (PDP) improvement, and moreover, 78% PDP improveme...

متن کامل

A new low power high reliability flip-flop robust against process variations

Low scaling technology makes a significant reduction in dimension and supply voltage, and lead to new challenges about power consumption such as increasing nodes sensitivity over radiation-induced soft errors in VLSI circuits. In this area, different design methods have been proposed to low power flip-flops and various research studies have been done to reach a suitable hardened flip-flops. In ...

متن کامل

Low Power Level Converting Flip-flop Design by Using Conditional Discharge Technique

Clustered Voltage Scaling (CVS) is an effective way to reduce power consumption in digital integrated circuits. Level-converting flip-flops are the critical elements in the CVS scheme. A single edge implicit pulse-triggered level-converting flip-flop with a conditional clock technique is used in the existing system. It increases the data switching activity due to longer delay. So the power cons...

متن کامل

Design of Low Power Level-Converting Retention Flip-Flop using LSSR technique for Zigbee SoCs

In this paper, we propose the design of low power level-converting retention flip-flop (RFF)using LSSR technique for Zigbee System-onchips (SoCs).The proposed retention flip-flop allows the voltage regulator which generates the core supply voltage (VDD, core) is turned off during the standby mode and thus reduces the standby power and dc current of the Zigbee SoCs. This method is the combinatio...

متن کامل

Self-Precharging Flip-Flop (SPFF): A New Level Converting Flip-Flop

Clustered voltage scaling scheme is an effective method of power consumption reduction without performance degradation. One of the main issues in this scheme is performance and power penalties due to insertion of level converting flip-flops at the interface from low-supply to high supply clusters to simultaneously perform latching and level converting functions. A new level converting flip-flop...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 26  شماره 3

صفحات  315- 322

تاریخ انتشار 2013-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023