Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

نویسندگان

  • Fatemeh Khosravi , Hormozgan University of Medical Sciences, Bandar Abbas, Iran
  • Saeed Kashani Hormozgan University of Medical Science, Bandar Abbas, Iran
چکیده مقاله:

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospective clinical trial was conducted on a total of 142 candidate patients 18 to 60 years of age with ASA I and II undergoing elective surgery. Patients were randomly divided into three groups: (1) mask ventilation (control group) (2) laryngeal mask airway and (3) combitube. At the next stage, the systolic and diastolic blood pressures and heart rates were measured at the following points in time: baseline, after induction of anesthesia and before airway manipulation, 1, 3 and 5 minutes after ventilation. The findings were analyzed and P<0.05 was considered significant. Correspondence: Hashem Jarineshin, MD. Anesthesiology, Critical Care and Pain Management Research Center, Hormozgan University of Medical Sciences. Bandar Abbas, Iran Tel:+98 9173613464 Email: [email protected] Results: Patients in all three groups were closely matched in terms of age, height, weight, sex and Mallampati score. The duration of combitube insertion was significantly longer than that of laryngeal mask airway (LMA) (P<0.05). The baseline and post-induction hemodynamic variables were similar in the three groups. The hemodynamic variations at the first minute were higher in the combitube group than the other two. At minute 3, the hemodynamic parameters in Groups 2 and 3 were significantly higher than those in Group 1. Moreover, diastolic blood pressure in Groups 2 and 3 was higher than that in Group 1 in the 5th minute. Conclusion: LMA insertion leads to lower hemodynamic responses in patients during airway management compared to combitube. This is can be an important issue in cardiovascular patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

better hemodynamic profile of laryngeal mask airway insertion compared to laryngoscopy and tracheal intubation

results participants in all groups were similar in terms of gender, age, weight, height, and mallampati class. the mean ± sd of sbps (105.62 ± 12.12, 112.90 ± 12.2, and 112.48 ± 15.14 mm hg, respectively for ett, lma-c, and lma-s) and dbps (64.64 ± 10.23, 73.78 ± 9.70, and 71.20 ± 12.27 mm hg, respectively for ett, lma-c, and lma-s) were significantly lower in the ett group compared to lma grou...

متن کامل

success rate of airway devices insertion: laryngeal mask airway versus supraglottic gel device

results in the i-gel group, the success rate was 66.7% for placement on the first attempt, 16.7% for the second, and 3.33% for the third attempt. in the lma group, the success rates were 80.6% and 12.9% for the first and second attempts, respectively. failure in placement occurred in four cases in the i-gel and two cases in lma groups. the mean insertion time was not significantly different bet...

متن کامل

&quot;comparison of hemodynamic changes after insertion of laryngeal mask airway, facemask and endotracheal intubation&quot;

hemodynamic changes are major hazards of general anesthesia and are probably generated by direct laryngoscopy and endotracheal intubation. we designed this prospective randomised study to assess the cardiovascular changes after either laryngeal mask airway (lma), face mask (fm) or endotracheal tube (ett) insertion in the airway management of adult patients anesthetised with nitrous oxide and ha...

متن کامل

Better Hemodynamic Profile of Laryngeal Mask Airway Insertion Compared to Laryngoscopy and Tracheal Intubation

BACKGROUND Laryngoscopy and tracheal intubation can cause serious cardiovascular responses in patients such as hypertension, tachycardia, and arrhythmias. Alternative airway maintenance techniques may attenuate these hemodynamic stress responses. OBJECTIVES This study aimed to compare the immediate hemodynamic effects of the insertion of laryngeal mask airway supreme (LMA-S) and classic (LMA-...

متن کامل

Comparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study

Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...

متن کامل

Laryngeal mask airway insertion anaesthesia and insertion techniques.

Laryngeal Mask Airway has gained wide acceptance for routine airway management, difficult airway and in emergency situations. The classical method of insertion was recommended by Dr Brain. Over the years various induction and insertion techniques have been described with variable results. Combination of induction agents with narcotics, with or without small dose muscle relaxants has been found ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 20  شماره None

صفحات  345- 354

تاریخ انتشار 2017-02

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023