Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study
نویسندگان
چکیده مقاله:
Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods: Twenty MSPCs scanned with CBCT at central and peripheral localization at 18x16 and 8x8 cm FOV. The 2.5 mm periphery area of the MSPC cross-sectional image was evaluated. The metal artefact-area within this area was measured. Then, the artifact-area to total-area ratio was converted to form of a percentage. In addition to evaluation of crown periphery area, the lengths of the metal streaks artifacts were measured. The maximum linear dimension of the metal artifact was recorded from the crown margin for each MSPC in cross-sectional image in the bucco-lingual direction. All data collected were evaluated by Kruskal-Wallis analysis and Mann Whitney U test (P˂0,05). Results: No statistically significant differences were found in the artifacts-area measured (P=0.121). However, there was a statistically significant difference in linear dimension measurements of artifacts (P=0.000). In 18x16 cm FOV localization peripheral linear dimension measurements were higher than other FOV and localizations. Conclusion: Linear size artifacts of MSPC were found to be higher in peripheral positioning in wide FOV. However, according to this study, areas evaluated for metal artifacts caused by MSPCs are not affected by FOV and localization.
منابع مشابه
effect of exposure parameters on metal artifacts in cone beam computed tomography
objectives: the aim of this study was to assess the effect of tube current, kilovoltage peak (kvp), metal type, and the position of metal objects on metal artifacts in cone-beam computed tomography (cbct) images. materials and methods: titanium and cobalt-chromium rods were fabricated and placed in a dry human mandible. samples were scanned using a promax 3d cbct unit with different milli-amper...
متن کاملA comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study
Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...
متن کاملCorrelation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)
Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...
متن کاملAssessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography
OBJECTIVE The aim of this study was to assess artifacts induced by metallic restorations in three-dimensional (3D) dental surface models derived by cone-beam computed tomography (CBCT). METHODS Fifteen specimens, each with four extracted human premolars and molars embedded in a plaster block, were scanned by CBCT before and after the cavitated second premolars were restored with dental amalga...
متن کاملMetal Artifacts in Computed Tomography
Karin Andersson (2018): Metal Artifacts in Computed Tomography – impact of reduction methods on image quality and radiotherapy treatment planning. Örebro Studies in Medicine 172. Degradation of image quality by metal artifacts is a common problem in computed tomography (CT) imaging, which can limit the diagnostic value of a CT examination and also introduce inaccuracies in radiotherapy (RT) tre...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 9 شماره 2
صفحات 81- 87
تاریخ انتشار 2020-06-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023